Multi-limited-angle spectral CT image reconstruction based on average image induced relative total variation model

In recent years, spectral computed tomography (CT) has attracted extensive attention. The purpose of this study is to achieve a low-cost and fast energy spectral CT reconstruction algorithm by implementing multi-limited-angle scans. General spectral CT projection data are collected over a full-angular range of 360 degrees. We simulate multi-source spectral CT by using a pair of X-ray source/detector. To speed up scanning, multi-limited-angle scanning was used in each energy channel. On this basis, an average image induced relative total variation (Aii-RTV) with multi-limited-angle spectral CT image reconstruction model is proposed. The iterative algorithm is used to solve Aii-RTV. Before iteration, the weighted average projection data of the multi-limited-angle energy spectral is carried out. In each step of the iterative algorithm flow is as follows: First, the relative total variation (RTV) reconstruction model is used to reconstruct the average image using average projection data. Then, the partial derivative of the average image is used to calculate the inherent variation in RTV model due to the integrity of the average image, and take its reciprocal as the weight coefficient of the windowing total variation of each energy channel reconstruction image. Finally, the average energy image is used to guide the multi-limited-angle projection data to reconstruct the image of each energy channel so as to suppress the limited-angle artifact of each energy channel image. In addition, we also discuss the influence of parameter selection on reconstructed image quality, which is important for regularization model. Through the reconstruction of multi-limited-angle spectral CT projection data, quantitative results and reconstructed images show that our algorithm has better performance than prior image constrained compressed sensing (PICCS) and RTV. The average PSNR of our reconstruction results in different channels was 35.6273, 4.533 and 2.301 higher than RTV (31.0943) and PICCS (33.3263), respectively.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2025-03-17
DOI
https://doi.org/10.1177/08953996251314771
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-limited-angle spectral CT image reconstruction based on average image induced relative total variation model

Yumeng Guo, Zhaoqiang Shen
Journal of X-Ray Science and Technology
Advanced X-ray and CT Imaging
article

Multi-limited-angle spectral CT image reconstruction based on average image induced relative total variation model

Yumeng Guo, Zhaoqiang Shen
article en

Abstract

In recent years, spectral computed tomography (CT) has attracted extensive attention. The purpose of this study is to achieve a low-cost and fast energy spectral CT reconstruction algorithm by implementing multi-limited-angle scans. General spectral CT projection data are collected over a full-angular range of 360 degrees. We simulate multi-source spectral CT by using a pair of X-ray source/detector. To speed up scanning, multi-limited-angle scanning was used in each energy channel. On this basis, an average image induced relative total variation (Aii-RTV) with multi-limited-angle spectral CT image reconstruction model is proposed. The iterative algorithm is used to solve Aii-RTV. Before iteration, the weighted average projection data of the multi-limited-angle energy spectral is carried out. In each step of the iterative algorithm flow is as follows: First, the relative total variation (RTV) reconstruction model is used to reconstruct the average image using average projection data. Then, the partial derivative of the average image is used to calculate the inherent variation in RTV model due to the integrity of the average image, and take its reciprocal as the weight coefficient of the windowing total variation of each energy channel reconstruction image. Finally, the average energy image is used to guide the multi-limited-angle projection data to reconstruct the image of each energy channel so as to suppress the limited-angle artifact of each energy channel image. In addition, we also discuss the influence of parameter selection on reconstructed image quality, which is important for regularization model. Through the reconstruction of multi-limited-angle spectral CT projection data, quantitative results and reconstructed images show that our algorithm has better performance than prior image constrained compressed sensing (PICCS) and RTV. The average PSNR of our reconstruction results in different channels was 35.6273, 4.533 and 2.301 higher than RTV (31.0943) and PICCS (33.3263), respectively.

Journal of X-Ray Science and TechnologyVol. 33(3)
Ningbo University (CN), Chongqing Technology and Business University (CN)
Innovative Research Group Project of the National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 95%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.