Parallel operation of common PLL-based synchronverters under transient conditions

Generally, a parallel connection of generators is required to meet the power need to supply the load demand. As a preferable replacement for typical generation units, a topology based on three-phase voltage source converters has been proposed. This paper proposes an approach based on virtual synchronous generator-based synchronverters for parallel operation of alternators. This approach automatically exchanges active and reactive power between parallel operated inverters of the same kind. Furthermore, to serve the purpose of synchronization, a Phase Locked Loop (PLL) is used. To avoid the tuning complexities and stability margin issue, a common PLL is used for both the converters. The PLL detects the grid voltage angle and helps with initial synchronization of the synchronverter in an easier way. The simulation studies are carried out to validate the performance and control of the proposed system. In addition, stability analysis has been performed using a state space approach to prove the efficacy of the system.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0227156
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parallel operation of common PLL-based synchronverters under transient conditions

Kuan Tak Tan, S. P. Gawande, Shamshad Alam, Pranjali M. Meshram et al.
AIP Advances
Microgrid Control and Optimization
article

Parallel operation of common PLL-based synchronverters under transient conditions

Kuan Tak Tan, S. P. Gawande, Shamshad Alam, Pranjali M. Meshram, Osamah J. Al-sareji, Ujwalla Gawande, Salah J. Mohammed, Khalid Ansari, Abdullah I. Al‐Mansour, Hasan Sh. Majdi
article en

Abstract

Generally, a parallel connection of generators is required to meet the power need to supply the load demand. As a preferable replacement for typical generation units, a topology based on three-phase voltage source converters has been proposed. This paper proposes an approach based on virtual synchronous generator-based synchronverters for parallel operation of alternators. This approach automatically exchanges active and reactive power between parallel operated inverters of the same kind. Furthermore, to serve the purpose of synchronization, a Phase Locked Loop (PLL) is used. To avoid the tuning complexities and stability margin issue, a common PLL is used for both the converters. The PLL detects the grid voltage angle and helps with initial synchronization of the synchronverter in an easier way. The simulation studies are carried out to validate the performance and control of the proposed system. In addition, stability analysis has been performed using a state space approach to prove the efficacy of the system.

AIP AdvancesVol. 15(3)
University of Pannonia (HU), Singapore Institute of Technology (SG), Dijlah University College (IQ), King Saud University (SA)
King Saud University
Openalex Percentile: Top 95%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parallel operation of common PLL-based synchronverters under transient conditions — Kuan Tak Tan, S. P. Gawande, et al. · AIP Advances (2025) | TGRS Research Map | TGRS