High-Purity Strontium Carbonate Shows the Narrowest Peak Width of Raman Scattered Light

Raman microscopes are widely used in various fields and their spectral resolutions differ greatly depending on the system and optical components. Thus, it is important to evaluate the spectral resolution of Raman systems under measurement conditions. Although calcite is a crystal with a trigonal structure and its narrow peak at ∼1086 cm<sup>-1</sup> has been used to evaluate the spectral resolution of Raman spectrometers, the peak width of calcite itself, ∼1.3 cm<sup>-1</sup> at full width half-maximum (FWHM), is not negligible under high spectral resolution conditions. Because the calcite peak at ∼1086 cm<sup>-1</sup> originates from symmetric stretching, which is a common vibration mode for carbonate salts, we examined strontium carbonate (SrCO<sub>3</sub>), barium carbonate (BaCO<sub>3</sub>), and lead carbonate (PbCO<sub>3</sub>) reagents to find a material having a narrower peak width than calcite. SrCO<sub>3</sub>, BaCO<sub>3</sub>, and PbCO<sub>3</sub> peaks originating from symmetric stretching were observed at 1072, 1059, and 1054 cm<sup>-1</sup>, respectively, and their peak widths at FWHM (0.67, 0.92, and 1.09 cm<sup>-1</sup>, respectively) were narrower than that of calcite (1.36 cm<sup>-1</sup>). The narrow peak width of SrCO<sub>3</sub> was strongly dependent on its purity, probably due to its high structural regularity, and the change in the peak width (FWHM) was only 0.12 cm<sup>-1</sup> between 5 °C and 45 °C. Thus, we concluded that the high-purity SrCO<sub>3</sub> peak at 1072 cm<sup>-1</sup> was the narrowest peak of Raman scattering light under ambient conditions and is suitable for evaluating high spectral resolution for Raman spectrometers.

Authors

Institutions

Publication Details

Journal
Applied Spectroscopy
Published
2025-03-17
DOI
https://doi.org/10.1177/00037028251318757
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Purity Strontium Carbonate Shows the Narrowest Peak Width of Raman Scattered Light

Nobuyasu Itoh
1 citations
Applied Spectroscopy
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

High-Purity Strontium Carbonate Shows the Narrowest Peak Width of Raman Scattered Light

Nobuyasu Itoh
article en
1 citations

Abstract

Raman microscopes are widely used in various fields and their spectral resolutions differ greatly depending on the system and optical components. Thus, it is important to evaluate the spectral resolution of Raman systems under measurement conditions. Although calcite is a crystal with a trigonal structure and its narrow peak at ∼1086 cm<sup>-1</sup> has been used to evaluate the spectral resolution of Raman spectrometers, the peak width of calcite itself, ∼1.3 cm<sup>-1</sup> at full width half-maximum (FWHM), is not negligible under high spectral resolution conditions. Because the calcite peak at ∼1086 cm<sup>-1</sup> originates from symmetric stretching, which is a common vibration mode for carbonate salts, we examined strontium carbonate (SrCO<sub>3</sub>), barium carbonate (BaCO<sub>3</sub>), and lead carbonate (PbCO<sub>3</sub>) reagents to find a material having a narrower peak width than calcite. SrCO<sub>3</sub>, BaCO<sub>3</sub>, and PbCO<sub>3</sub> peaks originating from symmetric stretching were observed at 1072, 1059, and 1054 cm<sup>-1</sup>, respectively, and their peak widths at FWHM (0.67, 0.92, and 1.09 cm<sup>-1</sup>, respectively) were narrower than that of calcite (1.36 cm<sup>-1</sup>). The narrow peak width of SrCO<sub>3</sub> was strongly dependent on its purity, probably due to its high structural regularity, and the change in the peak width (FWHM) was only 0.12 cm<sup>-1</sup> between 5 °C and 45 °C. Thus, we concluded that the high-purity SrCO<sub>3</sub> peak at 1072 cm<sup>-1</sup> was the narrowest peak of Raman scattering light under ambient conditions and is suitable for evaluating high spectral resolution for Raman spectrometers.

Applied SpectroscopyVol. 79(11)
National Institute of Advanced Industrial Science and Technology (JP)
Openalex Percentile: Top 16%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.