Patient-Specific Instrumentation Benefits for INBONE II Total Ankle Arthroplasty

Submission Type: Total Ankle Arthroplasty Research Type: Level 3 - Retrospective cohort study, Case-control study, Meta-analysis of Level 3 studies Introduction/Purpose: Total ankle arthroplasty (TAA) is a surgical procedure that has been shown to effectively reduce pain and improve mobility in patients with ankle arthritis. Achieving optimal alignment is crucial for implant longevity and patient outcomes. The PROPHECY patient-specific instrumentation (PSI) (Stryker, Mahwah, NJ, USA) has been developed to aid in accurate and efficient implant placement, including the INBONE II implant, which has been shown to offer enhanced stability and alignment correction. This study aimed to determine the accuracy of PSI regarding implant alignment and implant size, and compare outcomes between PSI implantation and the traditional jig method. We hypothesized that compared to the standard jig method (non-PSI group), PSI will improve alignment accuracy, deformity correction, and reduce radiation exposure, tourniquet and operative time. Methods: This retrospective study of 92 patients (46 PSI and 46 non-PSI cases) was performed at a single institution between 2006-2024 and included patients who had a TAA with INBONE II implants. The PSI group (n=46) was matched with the non-PSI group (n=46) by age (+/- 3 years) and sex. Chart review was performed to collect demographic data including primary surgeon, concomitant procedures, body mass index (BMI), age, tibial and talus implant sizes, total procedure time and total inflated tourniquet time. Intraoperative radiographs were used for fluoroscopy time. Radiographic evaluation using the Picture Archiving and Communication System (PACS, Sectra Inc. Shelton CT) of pre- and post-operative radiographs were analyzed to assess the accuracy of PROPHECY by comparing alignment of the implant in the PSI group to the intended preoperative plan, as well as compare the post operative deviation of the tibiotalar angle (TTA) and talar tilt (TT) in both groups. Results: The PROPHECY PSI demonstrated high accuracy in predicting correct implant size, 68% (n=32) of talus implants and 89% (n=42) of tibial implants. Most changes stemmed from downsizing the talus by one size. Median implant absolute deviation in the mortise and sagittal planes was less than 2 degrees, indicating accurate surgical alignment with the preoperative plan. 71% of PSI cases were performed by one surgeon, while a different surgeon with extensive experience with the jig performed 96% of the non-PSI cases. For both groups, median TTA deviation was less than 2 degrees and median post-operative TT was less than or equal to 1 degree. While no difference between groups for fluoroscopic time was found, the PSI group had a longer total inflated tourniquet and procedure time. Conclusion: For INBONE II implantation, PSI achieves similar alignment and implant sizing compared to standard instrumentation. Surgeons reliably and accurately aligned the tibial component per the preoperative plan. This study, the first to compare the two techniques with INBONE II, has strengths of matched pair analysis and validated outcomes. The longer tourniquet and operative time in the PSI group likely reflects the primary surgeon’s initial experience with the guides, while a surgeon experienced with the jig opted for the extramedullary approach. The patient-specific approach may help less experienced surgeons achieve desired alignment with less operative time. Accuracy and Alignment of Patient-Specific Instrumentation in Comparison with Prophecy Predicted Values and Non-PSI Cases using Radiographic and Intraoperative Measurements

Authors

Publication Details

Journal
Foot & Ankle Orthopaedics
Published
2025-01-01
DOI
https://doi.org/10.1177/2473011425s00072
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-Specific Instrumentation Benefits for INBONE II Total Ankle Arthroplasty

Allison L. Boden, Suzy Wang, Matthew S. Conti, Scott J. Ellis et al.
Foot & Ankle Orthopaedics
Foot and Ankle Surgery
article

Patient-Specific Instrumentation Benefits for INBONE II Total Ankle Arthroplasty

Allison L. Boden, Suzy Wang, Matthew S. Conti, Scott J. Ellis, Constantine A. Demetracopoulos, Patricia Friedmann, Jensen K. Henry, Ricardo Villar, Elizabeth A. Cody, Jonathan T. Deland, Charlotte Jones
article en

Abstract

Submission Type: Total Ankle Arthroplasty Research Type: Level 3 - Retrospective cohort study, Case-control study, Meta-analysis of Level 3 studies Introduction/Purpose: Total ankle arthroplasty (TAA) is a surgical procedure that has been shown to effectively reduce pain and improve mobility in patients with ankle arthritis. Achieving optimal alignment is crucial for implant longevity and patient outcomes. The PROPHECY patient-specific instrumentation (PSI) (Stryker, Mahwah, NJ, USA) has been developed to aid in accurate and efficient implant placement, including the INBONE II implant, which has been shown to offer enhanced stability and alignment correction. This study aimed to determine the accuracy of PSI regarding implant alignment and implant size, and compare outcomes between PSI implantation and the traditional jig method. We hypothesized that compared to the standard jig method (non-PSI group), PSI will improve alignment accuracy, deformity correction, and reduce radiation exposure, tourniquet and operative time. Methods: This retrospective study of 92 patients (46 PSI and 46 non-PSI cases) was performed at a single institution between 2006-2024 and included patients who had a TAA with INBONE II implants. The PSI group (n=46) was matched with the non-PSI group (n=46) by age (+/- 3 years) and sex. Chart review was performed to collect demographic data including primary surgeon, concomitant procedures, body mass index (BMI), age, tibial and talus implant sizes, total procedure time and total inflated tourniquet time. Intraoperative radiographs were used for fluoroscopy time. Radiographic evaluation using the Picture Archiving and Communication System (PACS, Sectra Inc. Shelton CT) of pre- and post-operative radiographs were analyzed to assess the accuracy of PROPHECY by comparing alignment of the implant in the PSI group to the intended preoperative plan, as well as compare the post operative deviation of the tibiotalar angle (TTA) and talar tilt (TT) in both groups. Results: The PROPHECY PSI demonstrated high accuracy in predicting correct implant size, 68% (n=32) of talus implants and 89% (n=42) of tibial implants. Most changes stemmed from downsizing the talus by one size. Median implant absolute deviation in the mortise and sagittal planes was less than 2 degrees, indicating accurate surgical alignment with the preoperative plan. 71% of PSI cases were performed by one surgeon, while a different surgeon with extensive experience with the jig performed 96% of the non-PSI cases. For both groups, median TTA deviation was less than 2 degrees and median post-operative TT was less than or equal to 1 degree. While no difference between groups for fluoroscopic time was found, the PSI group had a longer total inflated tourniquet and procedure time. Conclusion: For INBONE II implantation, PSI achieves similar alignment and implant sizing compared to standard instrumentation. Surgeons reliably and accurately aligned the tibial component per the preoperative plan. This study, the first to compare the two techniques with INBONE II, has strengths of matched pair analysis and validated outcomes. The longer tourniquet and operative time in the PSI group likely reflects the primary surgeon’s initial experience with the guides, while a surgeon experienced with the jig opted for the extramedullary approach. The patient-specific approach may help less experienced surgeons achieve desired alignment with less operative time. Accuracy and Alignment of Patient-Specific Instrumentation in Comparison with Prophecy Predicted Values and Non-PSI Cases using Radiographic and Intraoperative Measurements

Foot & Ankle OrthopaedicsVol. 10(1)
Openalex Percentile: Top 94%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.