COMMUTATING PROCESS IN A THREE-PHASE TWO-BRIDGE COMPENSATION CONVERTER

The article presents the results of the analysis of energy processes in the studied compensating converter at a four-fold frequency of transistor control pulses. The presence of three operating modes differing in the pattern of change in the phase current of the capacitor battery is revealed. One of these modes is studied in detail. A new scientific result is obtained. It shows that in the case when the commutating process in the power electric valve of one phase occurs in the operating interval of the transistor of the commutating link of the next phase, the value of the commutating voltage at the moment of commutating does not depend on the delay in supplying control pulses to the transistors. To confirm and verify the obtained results, circuit simulation in the Micro Cap package is used. The modeling technique is described, its results are presented, and the results are analyzed. A comparative analysis of the numerical values ​​of the characteristics of the energy processes of the studied converter obtained as a result of analytical calculation and circuit simulation showed that the discrepancy does not exceed 4%. This indicates the adequacy of the applied modeling technique and acceptable accuracy of the results of analytical calculations. Refer. 6, fig. 4.

Authors

Publication Details

Journal
POWER ENGINEERING economics technique ecology
Published
2025-03-17
DOI
https://doi.org/10.20535/1813-5420.1.2025.324269
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMMUTATING PROCESS IN A THREE-PHASE TWO-BRIDGE COMPENSATION CONVERTER

В.С. Бойко, Oleksandr Shkardun
POWER ENGINEERING economics technique ecology
Advanced DC-DC Converters
article

COMMUTATING PROCESS IN A THREE-PHASE TWO-BRIDGE COMPENSATION CONVERTER

В.С. Бойко, Oleksandr Shkardun
article en

Abstract

The article presents the results of the analysis of energy processes in the studied compensating converter at a four-fold frequency of transistor control pulses. The presence of three operating modes differing in the pattern of change in the phase current of the capacitor battery is revealed. One of these modes is studied in detail. A new scientific result is obtained. It shows that in the case when the commutating process in the power electric valve of one phase occurs in the operating interval of the transistor of the commutating link of the next phase, the value of the commutating voltage at the moment of commutating does not depend on the delay in supplying control pulses to the transistors. To confirm and verify the obtained results, circuit simulation in the Micro Cap package is used. The modeling technique is described, its results are presented, and the results are analyzed. A comparative analysis of the numerical values ​​of the characteristics of the energy processes of the studied converter obtained as a result of analytical calculation and circuit simulation showed that the discrepancy does not exceed 4%. This indicates the adequacy of the applied modeling technique and acceptable accuracy of the results of analytical calculations. Refer. 6, fig. 4.

POWER ENGINEERING economics technique ecology(1)
Openalex Percentile: Top 96%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.