Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels

This study aims to leverage available experimental data on the myogenic and endothelial responses of the microvessels to calibrate the parameters and refine the functional form of the compliance feedback model. The experimental data used in this study trace the changes in the vessel calibre of individual arteriolar vessels in response to changes in the intraluminal pressure and/or the pressure gradient, which correspond to the myogenic and endothelial mechanisms, respectively. The compliance feedback model was previously developed to characterize the elastic and autoregulatory behavior of microvessels. We devise and employ a two-stage sequential Monte Carlo (MC) approximate Bayesian computation (ABC) scheme to obtain the posterior distribution of the model's parameters, such that the final parameter space distribution integrates information from any prior knowledge of the parameters, the model dynamics, and the available experimental data. Furthermore, the calibration scheme provides key insights into the underlying mechanistic features of the dynamical system; namely, the ABC scheme reveals that there is a marked difference in the time constants between the myogenic-induced dilation and constriction. Overall, upon parameter calibration, the computationally low-cost compliance feedback model achieves very good agreement with the experimental measurements, despite limited data availability, demonstrating that the model provides a simple, compact, yet robust and physiologically grounded characterization of the autoregulatory response, all of which are essential attributes to increase the translatability of hemodynamic models into the clinical environment for future clinical applications.

Authors

Institutions

Publication Details

Journal
International Journal for Numerical Methods in Biomedical Engineering
Published
2025-03-01
DOI
https://doi.org/10.1002/cnm.70023
Citations
2
Primary Topic
Blood properties and coagulation
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels

Ali Daher
2 citations
International Journal for Numerical Methods in Biomedical Engineering
Blood properties and coagulation
3.04
article

Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels

Ali Daher
article en
2 citations

Abstract

This study aims to leverage available experimental data on the myogenic and endothelial responses of the microvessels to calibrate the parameters and refine the functional form of the compliance feedback model. The experimental data used in this study trace the changes in the vessel calibre of individual arteriolar vessels in response to changes in the intraluminal pressure and/or the pressure gradient, which correspond to the myogenic and endothelial mechanisms, respectively. The compliance feedback model was previously developed to characterize the elastic and autoregulatory behavior of microvessels. We devise and employ a two-stage sequential Monte Carlo (MC) approximate Bayesian computation (ABC) scheme to obtain the posterior distribution of the model's parameters, such that the final parameter space distribution integrates information from any prior knowledge of the parameters, the model dynamics, and the available experimental data. Furthermore, the calibration scheme provides key insights into the underlying mechanistic features of the dynamical system; namely, the ABC scheme reveals that there is a marked difference in the time constants between the myogenic-induced dilation and constriction. Overall, upon parameter calibration, the computationally low-cost compliance feedback model achieves very good agreement with the experimental measurements, despite limited data availability, demonstrating that the model provides a simple, compact, yet robust and physiologically grounded characterization of the autoregulatory response, all of which are essential attributes to increase the translatability of hemodynamic models into the clinical environment for future clinical applications.

International Journal for Numerical Methods in Biomedical EngineeringVol. 41(3)
University of Oxford (GB)
Life below water
Openalex Percentile: Top 11%
Blood properties and coagulation
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using Approximate Bayesian Computation to Calibrate the Model Parameters Characterizing the Autoregulatory Behavior of Microvessels — Ali Daher · International Journal for Numerical Methods in Biomedical Engineering (2025) | TGRS Research Map | TGRS