Second-Order Effects in Lightweight Aggregate Concrete Slender Columns

This paper covers the analysis of the behavior of columns made of LWAC (Lightweight Aggregate Concrete), which can be used as a substitute for normal-density concrete. This work presents an experimental research program focused on second-order effects in slender elements (λ = 74) made of LWAC and normal-density concrete tested under eccentric load. Elements with two ratios of longitudinal reinforcement (0.9%, 2.3%) were considered. Despite the similar compressive strengths of the concrete, the significantly different moduli of elasticity of the two types of concrete caused the lightweight concrete columns to show higher displacements, leading to their lower load bearing capacity. This disproportion was more pronounced for low longitudinal reinforcement. In the second part of this experiment, the behavior of the columns was simulated using models taken from the literature. The analysis showed that the models often do not accurately predict the elastic modulus or LWAC limit strain of concrete, so when trying to predict the behavior of this type of element accurately, these parameters should be determined experimentally.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-03-16
DOI
https://doi.org/10.3390/ma18061312
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Second-Order Effects in Lightweight Aggregate Concrete Slender Columns

Richard Dvořák, Tomasz Waśniewski, Ewelina Kołodziejczyk, Martyna Rabenda et al.
Materials
Structural Behavior of Reinforced Concrete
article

Second-Order Effects in Lightweight Aggregate Concrete Slender Columns

Richard Dvořák, Tomasz Waśniewski, Ewelina Kołodziejczyk, Martyna Rabenda, Vojtěch Starý
article en

Abstract

This paper covers the analysis of the behavior of columns made of LWAC (Lightweight Aggregate Concrete), which can be used as a substitute for normal-density concrete. This work presents an experimental research program focused on second-order effects in slender elements (λ = 74) made of LWAC and normal-density concrete tested under eccentric load. Elements with two ratios of longitudinal reinforcement (0.9%, 2.3%) were considered. Despite the similar compressive strengths of the concrete, the significantly different moduli of elasticity of the two types of concrete caused the lightweight concrete columns to show higher displacements, leading to their lower load bearing capacity. This disproportion was more pronounced for low longitudinal reinforcement. In the second part of this experiment, the behavior of the columns was simulated using models taken from the literature. The analysis showed that the models often do not accurately predict the elastic modulus or LWAC limit strain of concrete, so when trying to predict the behavior of this type of element accurately, these parameters should be determined experimentally.

MaterialsVol. 18(6)
Lodz University of Technology (PL), Czech Technical University in Prague (CZ), Brno University of Technology (CZ)
Sustainable cities and communities
Openalex Percentile: Top 96%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.