Stub Setting Fixture Prototype on High Voltage Overhead Transmission Line Tower Installation

High voltage overhead transmission line is a transmission tower used to conduct electricity with a voltage of 35 kV to 230 kV. In the installation of the HV overhead transmission line tower structure, one of the main things that need to be considered is the installation of stub that can affect the sturdiness of the tower. This research aims to design and make a stub setting fixture on the HV overhead transmission tower installation. The research process began with data observation and literature study of tower stub installation in the 150kV 2xZebra Andolo – Kasipute Sec.1 installation project of PT. PLN Persero UIP South Sulawesi, then designed the stub setting fixture components, design data analysis, and fixture manufacturing. The results of the analysis of the design structure experienced do not exceed the limits of the material stresses of the component, the analysis of machine elements in the stub setting fixture is able to withstand the loads experienced by the component. It is expected that there will be improvements and development of fixture in the form of more efficient forms of construction and operation, and can use analog and digital controls in terms of fixture operation in subsequent development and research.

Authors

Institutions

Publication Details

Journal
Engineering headway
Published
2025-03-17
DOI
https://doi.org/10.4028/p-1nqbxg
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stub Setting Fixture Prototype on High Voltage Overhead Transmission Line Tower Installation

Hairul Arsyad, Nasruddin Azis, Muhammad Reza Buanaputra
Engineering headway
Thermal Analysis in Power Transmission
article

Stub Setting Fixture Prototype on High Voltage Overhead Transmission Line Tower Installation

Hairul Arsyad, Nasruddin Azis, Muhammad Reza Buanaputra
article en

Abstract

High voltage overhead transmission line is a transmission tower used to conduct electricity with a voltage of 35 kV to 230 kV. In the installation of the HV overhead transmission line tower structure, one of the main things that need to be considered is the installation of stub that can affect the sturdiness of the tower. This research aims to design and make a stub setting fixture on the HV overhead transmission tower installation. The research process began with data observation and literature study of tower stub installation in the 150kV 2xZebra Andolo – Kasipute Sec.1 installation project of PT. PLN Persero UIP South Sulawesi, then designed the stub setting fixture components, design data analysis, and fixture manufacturing. The results of the analysis of the design structure experienced do not exceed the limits of the material stresses of the component, the analysis of machine elements in the stub setting fixture is able to withstand the loads experienced by the component. It is expected that there will be improvements and development of fixture in the form of more efficient forms of construction and operation, and can use analog and digital controls in terms of fixture operation in subsequent development and research.

Engineering headwayVol. 20
Hasanuddin University (ID)
Openalex Percentile: Top 95%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.