Towards a New MAX-DOAS Measurement Site in the Po Valley: Aerosol Optical Depth and NO2 Tropospheric VCDs

Pollutants information can be retrieved from visible (VIS) and ultraviolet (UV) diffuse solar spectra exploiting Multi-AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) instruments. In May 2021, the Italian research institute CNR-ISAC acquired and deployed a MAX-DOAS system SkySpec-2D. It is located in the “Giorgio Fea” observatory in San Pietro Capofiume (SPC), in the middle of the Po Valley, where it has constantly acquired zenith and off-axis diffuse solar spectra since the 1st October 2021. This work presents the retrieved tropospheric NO2 and aerosol extinction profiles (and their columns) derived from the MAX-DOAS measurements using the newly developed DEAP retrieval code. The code has been validated both using synthetic differential Slant Column Densities (dSCDs) from the Fiducial Reference Measurements for Ground-Based DOAS Air-Quality Observations (FRM4DOAS) project and real measured data. For this purpose, DEAP results are compared with the ones obtained with three state-of-the-art retrieval codes. In addition, an inter-comparison with satellite products from Sentinel-5P TROPOMI, for the tropospheric NO2 Vertical Column Densities (VCDs), and MODIS-MAIAC for the tropospheric Aerosol Optical Depth (AOD), is performed. We find a bias of −0.6 × 1015 molec/cm2 with a standard deviation of 1.8 × 1015 molec/cm2 with respect to Sentinel-5P TROPOMI for NO2 tropospheric VCDs and of 0.04 ± 0.08 for AOD with respect to MODIS-MAIAC data. The retrieved data show that the SPC measurement site is representative of the background pollution conditions of the Po Valley. For this reason, it is a good candidate for satellite validation and scientific studies over the Po Valley.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2025-03-15
DOI
https://doi.org/10.3390/rs17061035
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards a New MAX-DOAS Measurement Site in the Po Valley: Aerosol Optical Depth and NO2 Tropospheric VCDs

Martina M. Friedrich, Enzo Papandrea, Massimo Valeri, Paolo Pettinari et al.
Remote Sensing
Atmospheric and Environmental Gas Dynamics
article

Towards a New MAX-DOAS Measurement Site in the Po Valley: Aerosol Optical Depth and NO2 Tropospheric VCDs

Martina M. Friedrich, Enzo Papandrea, Massimo Valeri, Paolo Pettinari, Thomas Wagner, Elisa Castelli, Tim Bösch, Andreas Richter, Margherita Premuda, Michel Van Roozendaël, Andrè Achilli, Steffen Beirle, François Hendrick, Caroline Fayt
article en

Abstract

Pollutants information can be retrieved from visible (VIS) and ultraviolet (UV) diffuse solar spectra exploiting Multi-AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) instruments. In May 2021, the Italian research institute CNR-ISAC acquired and deployed a MAX-DOAS system SkySpec-2D. It is located in the “Giorgio Fea” observatory in San Pietro Capofiume (SPC), in the middle of the Po Valley, where it has constantly acquired zenith and off-axis diffuse solar spectra since the 1st October 2021. This work presents the retrieved tropospheric NO2 and aerosol extinction profiles (and their columns) derived from the MAX-DOAS measurements using the newly developed DEAP retrieval code. The code has been validated both using synthetic differential Slant Column Densities (dSCDs) from the Fiducial Reference Measurements for Ground-Based DOAS Air-Quality Observations (FRM4DOAS) project and real measured data. For this purpose, DEAP results are compared with the ones obtained with three state-of-the-art retrieval codes. In addition, an inter-comparison with satellite products from Sentinel-5P TROPOMI, for the tropospheric NO2 Vertical Column Densities (VCDs), and MODIS-MAIAC for the tropospheric Aerosol Optical Depth (AOD), is performed. We find a bias of −0.6 × 1015 molec/cm2 with a standard deviation of 1.8 × 1015 molec/cm2 with respect to Sentinel-5P TROPOMI for NO2 tropospheric VCDs and of 0.04 ± 0.08 for AOD with respect to MODIS-MAIAC data. The retrieved data show that the SPC measurement site is representative of the background pollution conditions of the Po Valley. For this reason, it is a good candidate for satellite validation and scientific studies over the Po Valley.

Remote SensingVol. 17(6)
Alfred-Wegener-Institut Helmholtz-Zentrum für Polar- und Meeresforschung (DE), University of Bremen (DE), Royal Belgian Institute for Space Aeronomy (BE), Serco (United Kingdom) (GB), Institute of Atmospheric Sciences and Climate (IT), Max Planck Institute for Chemistry (DE), National Research Council (IT), University of Bologna (IT)
Openalex Percentile: Top 94%
Atmospheric and Environmental Gas Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.