Variations in thromboelastography levels in blood exposed to membrane oxygenators

IntroductionThromboelastography (TEG), which indicates hemostatic ability, is useful for monitoring coagulation during extracorporeal circulation (ECC). However, the extent to which TEG levels are independently affected by ECC exposure remains unclear. To determine the effects of TEG levels in blood exposed to a membrane oxygenator, we performed in vitro experiments using whole human blood with ECC circuits including a membrane oxygenator.MethodsBlood provided by healthy volunteers was heparinized and circulated in three types of experimental circuits: polymer-coating, heparin-coating (HC), or non-coating (NC) membrane oxygenators (five of each type). Thromboelastography tests using a global hemostasis assay were performed at 3, 6, 12, and 24 h of circulation in each experiment. During TEG, the sampled blood was reversed with 0.05 mg of protamine. One-way analysis of variance (ANOVA) and two-way repeated measures ANOVA were performed to evaluate trends in circulation duration and coating types, respectively.ResultsCitrated kaolin with heparinase reaction times (CKHR) were significantly shortened at 6 and 12 h but prolonged at 24 h. The maximum amplitude for citrated kaolin with heparinase (CKHMA) was magnified from 6 to 12 h. Regarding the coating type, a significant difference was observed between HC and NC in CKHR at 6 h, but significance was not noted in other comparisons of coating types in CKHR and CKHMA.ConclusionsThromboelastography data indicated that the hemostatic capability of blood exposed to membrane surfaces was maintained after 12 h of circulation. The effects on TEG data in terms of coating type remain to be determined.

Authors

Institutions

Publication Details

Journal
Asian Cardiovascular and Thoracic Annals
Published
2025-03-01
DOI
https://doi.org/10.1177/02184923251327042
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variations in thromboelastography levels in blood exposed to membrane oxygenators

Masashi Tagaya, Takuo Murataka, Shunsuke Takahashi, Shunsuke Ichikawa et al.
Asian Cardiovascular and Thoracic Annals
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

Variations in thromboelastography levels in blood exposed to membrane oxygenators

Masashi Tagaya, Takuo Murataka, Shunsuke Takahashi, Shunsuke Ichikawa, H Handa, S. Okano
article en

Abstract

IntroductionThromboelastography (TEG), which indicates hemostatic ability, is useful for monitoring coagulation during extracorporeal circulation (ECC). However, the extent to which TEG levels are independently affected by ECC exposure remains unclear. To determine the effects of TEG levels in blood exposed to a membrane oxygenator, we performed in vitro experiments using whole human blood with ECC circuits including a membrane oxygenator.MethodsBlood provided by healthy volunteers was heparinized and circulated in three types of experimental circuits: polymer-coating, heparin-coating (HC), or non-coating (NC) membrane oxygenators (five of each type). Thromboelastography tests using a global hemostasis assay were performed at 3, 6, 12, and 24 h of circulation in each experiment. During TEG, the sampled blood was reversed with 0.05 mg of protamine. One-way analysis of variance (ANOVA) and two-way repeated measures ANOVA were performed to evaluate trends in circulation duration and coating types, respectively.ResultsCitrated kaolin with heparinase reaction times (CKHR) were significantly shortened at 6 and 12 h but prolonged at 24 h. The maximum amplitude for citrated kaolin with heparinase (CKHMA) was magnified from 6 to 12 h. Regarding the coating type, a significant difference was observed between HC and NC in CKHR at 6 h, but significance was not noted in other comparisons of coating types in CKHR and CKHMA.ConclusionsThromboelastography data indicated that the hemostatic capability of blood exposed to membrane surfaces was maintained after 12 h of circulation. The effects on TEG data in terms of coating type remain to be determined.

Asian Cardiovascular and Thoracic AnnalsVol. 33(2-3)
National Hospital Organization (JP), Kure Medical Center (JP)
Good health and well-being
Openalex Percentile: Top 93%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Variations in thromboelastography levels in blood exposed to membrane oxygenators — Masashi Tagaya, Takuo Murataka, et al. · Asian Cardiovascular and Thoracic Annals (2025) | TGRS Research Map | TGRS