Physical, Mechanical, Radiation Shielding Properties of Self-Compacting Heavy Concrete

The purpose of this research is to ascertain the radiation, mechanical, and physical characteristics of self-compacting concrete with barite aggregate that has been prepared with various additives. Experiments were carried out on self-compacting heavy concrete samples produced using different additives to determine their physical and mechanical properties such as V-funnel, slump-spreading, collapse, compressive strength, air gap, density values of the samples, and radiation shielding values. The highest linear attenuation coefficient was 0.2859 cm⁻¹, observed in the concrete sample with CNT 4 additive. The lowest value (0.2775 cm⁻¹) was measured in the sample containing CNT 2. For CNT 1 and CNT 3, the linear attenuation coefficients were recorded as 0.2794 cm⁻¹ and 0.2818 cm⁻¹, respectively. Among the polycarboxylic ether-based additives, CNT 3 demonstrated the best radiation shielding properties.

Authors

Institutions

Publication Details

Journal
Karadeniz Fen Bilimleri Dergisi
Published
2025-03-15
DOI
https://doi.org/10.31466/kfbd.1504950
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physical, Mechanical, Radiation Shielding Properties of Self-Compacting Heavy Concrete

Şemsettin KILINÇARSLAN, Abdullah Coşkunsu, Yasemin Şi̇mşek Türker
Karadeniz Fen Bilimleri Dergisi
Radiation Shielding Materials Analysis
article

Physical, Mechanical, Radiation Shielding Properties of Self-Compacting Heavy Concrete

Şemsettin KILINÇARSLAN, Abdullah Coşkunsu, Yasemin Şi̇mşek Türker
article en

Abstract

The purpose of this research is to ascertain the radiation, mechanical, and physical characteristics of self-compacting concrete with barite aggregate that has been prepared with various additives. Experiments were carried out on self-compacting heavy concrete samples produced using different additives to determine their physical and mechanical properties such as V-funnel, slump-spreading, collapse, compressive strength, air gap, density values of the samples, and radiation shielding values. The highest linear attenuation coefficient was 0.2859 cm⁻¹, observed in the concrete sample with CNT 4 additive. The lowest value (0.2775 cm⁻¹) was measured in the sample containing CNT 2. For CNT 1 and CNT 3, the linear attenuation coefficients were recorded as 0.2794 cm⁻¹ and 0.2818 cm⁻¹, respectively. Among the polycarboxylic ether-based additives, CNT 3 demonstrated the best radiation shielding properties.

Karadeniz Fen Bilimleri DergisiVol. 15(1)
Suleyman Demirel University (KZ)
Openalex Percentile: Top 97%
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.