The Factors Affecting Calculations for Blue Green Laser of Different Turbidity Underwater System

The chief of laser reasons are analytic standards and it is the objective to restate the technique so that sufficient adjustment and variety of the basic strategy agree to the exact development. Using the express improvement of blue-green laser knowledge, Because of their excessive diffusion capacities, lasers have developed the maximum suitable equipment for the underwater detection. In the all-underwater laser systems, the redirected laser pulse which comprises the main data for the utmost of the scheme is extremely degraded beside the laser’s propagation path with reflection. We studied the impact of the angle of incidence, target distance and medium attenuation. A methodical analysis of the influential factors on the reflectance and ranging correctness was achieved in theory and experimentally systems are not dynamic in considering these waveform signals and the underwater cannot be appropriately disintegrated, resulting in succeeding statistics-processing errors. This work used a green-blue laser to detect the maximum distance for a swimming pool as the study through models of water has altered turbidity (pure, little & extraordinary turbid) with absorption coefficient, a(λ) to test with a distance of 12m for the system. The main reason for the transmission of the Gaussian with Green-Blue laser performance analysis is the established energy of CCD camera or high sensor working underwater. In addition, water tank instability mains to the rate of a BER floor in exact settings

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Applied Sciences and Engineering Technology
Published
2025-03-16
DOI
https://doi.org/10.37934/araset.63.2.4553
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Factors Affecting Calculations for Blue Green Laser of Different Turbidity Underwater System

Jameel Kadhim Abed, Muhammad Mohsin, Ahmed Hussein Duhis, Mohanad Aljanabi
Journal of Advanced Research in Applied Sciences and Engineering Technology
Water Quality Monitoring and Analysis
article

The Factors Affecting Calculations for Blue Green Laser of Different Turbidity Underwater System

Jameel Kadhim Abed, Muhammad Mohsin, Ahmed Hussein Duhis, Mohanad Aljanabi
article en

Abstract

The chief of laser reasons are analytic standards and it is the objective to restate the technique so that sufficient adjustment and variety of the basic strategy agree to the exact development. Using the express improvement of blue-green laser knowledge, Because of their excessive diffusion capacities, lasers have developed the maximum suitable equipment for the underwater detection. In the all-underwater laser systems, the redirected laser pulse which comprises the main data for the utmost of the scheme is extremely degraded beside the laser’s propagation path with reflection. We studied the impact of the angle of incidence, target distance and medium attenuation. A methodical analysis of the influential factors on the reflectance and ranging correctness was achieved in theory and experimentally systems are not dynamic in considering these waveform signals and the underwater cannot be appropriately disintegrated, resulting in succeeding statistics-processing errors. This work used a green-blue laser to detect the maximum distance for a swimming pool as the study through models of water has altered turbidity (pure, little & extraordinary turbid) with absorption coefficient, a(λ) to test with a distance of 12m for the system. The main reason for the transmission of the Gaussian with Green-Blue laser performance analysis is the established energy of CCD camera or high sensor working underwater. In addition, water tank instability mains to the rate of a BER floor in exact settings

Journal of Advanced Research in Applied Sciences and Engineering TechnologyVol. 63(2)
Alsalam University College (IQ), Al-Furat Al-Awsat Technical University (IQ)
Openalex Percentile: Top 94%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.