Thermodynamic Analysis of Vapor Compression Refrigeration System with Various Refrigerants

The study analyzes energy and exergy in the basic vapor compression refrigeration system. The system consists of four parts as expansion valve, condenser, evaporator and compressor. In each component, energy and exergy balance is employed and the effectiveness of the basic vapor compression refrigeration system is presented. In the study, to evaluate the impact of different refrigerants on system effectiveness, four different gases (R134a, R125, R141b, R423a) at constant dead state temperature (T0 = 25 oC) are analyzed. According to the results, while the COP of R134a is 2.50, the total exergy destruction is 2.31 kW. While the COP of R423a is 0.22, the total exergy destruction is 0.50kW. While the COP of R141b is 0.60, the total exergy destruction is 7.38kW. While the COP of R125 is 0.53, the total exergy destruction is 4.74kW.

Authors

Publication Details

Journal
Karadeniz Fen Bilimleri Dergisi
Published
2025-03-15
DOI
https://doi.org/10.31466/kfbd.1571839
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic Analysis of Vapor Compression Refrigeration System with Various Refrigerants

Atakan Tantekin
1 citations
Karadeniz Fen Bilimleri Dergisi
Refrigeration and Air Conditioning Technologies
0.71
article

Thermodynamic Analysis of Vapor Compression Refrigeration System with Various Refrigerants

Atakan Tantekin
article en
1 citations

Abstract

The study analyzes energy and exergy in the basic vapor compression refrigeration system. The system consists of four parts as expansion valve, condenser, evaporator and compressor. In each component, energy and exergy balance is employed and the effectiveness of the basic vapor compression refrigeration system is presented. In the study, to evaluate the impact of different refrigerants on system effectiveness, four different gases (R134a, R125, R141b, R423a) at constant dead state temperature (T0 = 25 oC) are analyzed. According to the results, while the COP of R134a is 2.50, the total exergy destruction is 2.31 kW. While the COP of R423a is 0.22, the total exergy destruction is 0.50kW. While the COP of R141b is 0.60, the total exergy destruction is 7.38kW. While the COP of R125 is 0.53, the total exergy destruction is 4.74kW.

Karadeniz Fen Bilimleri DergisiVol. 15(1)
Openalex Percentile: Top 35%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.