Horizontal and Vertical Profiling of the Proton Beam of Cyclotron C18/18 by Vibrating Wire Monitors of Modernized Diagnostic Station

The horizontal and vertical profiles of the proton beam of the cyclotron C18/18 were measured by a modernized diagnostic station based on vibrating wire monitors. Considering the results of the first experiments using monitors with an aperture of 14 mm and superimposed lead screens, monitors with an extended aperture (28 mm) and magnets removed from the beam exposure zone were developed. In addition, the sensors are assembled on a thick metal base that serves as a collimator for the beam. The problems of electromagnetic interference are solved by the fact that the electronic nodes of the station are assembled on the same base. Scanning in the new station is carried out in the same plane, as close as possible to the output flange of the cyclotron (54 mm). New software has been developed that normalizes the profiles by the maximum value. Test measurements of the proton beam profile in the range of the average beam current ~1 μA were carried out.

Authors

Institutions

Publication Details

Journal
Journal of Contemporary Physics (Armenian Academy of Sciences)
Published
2024-12-01
DOI
https://doi.org/10.1134/s1068337225700082
Citations
2
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Horizontal and Vertical Profiling of the Proton Beam of Cyclotron C18/18 by Vibrating Wire Monitors of Modernized Diagnostic Station

S.G. Arutunian, Э. Г. Лазарева, A. Aprahamian, G. V. Mirzoyan et al.
2 citations
Journal of Contemporary Physics (Armenian Academy of Sciences)
Nuclear Physics and Applications
1.22
article

Horizontal and Vertical Profiling of the Proton Beam of Cyclotron C18/18 by Vibrating Wire Monitors of Modernized Diagnostic Station

S.G. Arutunian, Э. Г. Лазарева, A. Aprahamian, G. V. Mirzoyan, R.S. Gevorgyan, М. Chung, N.M. Manukyan, A. Manukyan, A. V. Margaryan, L.M. Lazarev
article en
2 citations

Abstract

The horizontal and vertical profiles of the proton beam of the cyclotron C18/18 were measured by a modernized diagnostic station based on vibrating wire monitors. Considering the results of the first experiments using monitors with an aperture of 14 mm and superimposed lead screens, monitors with an extended aperture (28 mm) and magnets removed from the beam exposure zone were developed. In addition, the sensors are assembled on a thick metal base that serves as a collimator for the beam. The problems of electromagnetic interference are solved by the fact that the electronic nodes of the station are assembled on the same base. Scanning in the new station is carried out in the same plane, as close as possible to the output flange of the cyclotron (54 mm). New software has been developed that normalizes the profiles by the maximum value. Test measurements of the proton beam profile in the range of the average beam current ~1 μA were carried out.

Journal of Contemporary Physics (Armenian Academy of Sciences)Vol. 59(4)
University of Notre Dame (US), Pohang University of Science and Technology (KR), A. Alikhanyan National Laboratory (AM)
Affordable and clean energy
Openalex Percentile: Top 19%
Nuclear Physics and Applications
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.