Analysis of fiber reinforced thermoplastic pipe perforation and bulging failure in gas field
A polyester fiber-reinforced thermoplastic composite pipe (FRTP) utilized for high-pressure water transportation experienced perforation leakage and bulging rupture of the outer protective layer after 6 months of service. The study was conducted by physical and chemical properties test, thermal analysis, mechanical analysis, pressure performance analysis, and morphology analysis. The failure primarily due to a crack defect on the inner surface of the cross-linked polyethylene (PEX) of this pipe, which allowed it to pass the pressure test but led to failure after a period of operation. Under the continuous action of high pressure, the crack expands and the lining layer is perforated, forming a leakage point through which high-pressure fluid entered the interlayer and accumulated in the outer protective layer of the pipe body. This outer protective layer gradually thinned and the high-pressure fluid at the leakage point pierced through the pipe, forming a perforation failure on the pipe body.
Authors
- Han Ding
- Houbu Li (ORCID: https://orcid.org/0000-0002-7602-1305)
- Yanfei Qi (ORCID: https://orcid.org/0000-0003-1391-4111)
- Huilin Lun (ORCID: https://orcid.org/0009-0002-2462-2739)
- Bin Hu (ORCID: https://orcid.org/0000-0001-9814-5096)
- Aibo Zhang (ORCID: https://orcid.org/0000-0003-3632-5838)
Institutions
- University of British Columbia (CA)
- Northwestern Polytechnical University (CN)
- Tarim University (CN)
- China National Petroleum Corporation (China) (CN)
Publication Details
- Journal
- Journal of Thermoplastic Composite Materials
- Published
- 2025-03-15
- DOI
- https://doi.org/10.1177/08927057251327351
- Citations
- 1
- Primary Topic
- Mechanical Behavior of Composites
- Type
- article
- Field-Weighted Citation Impact
- 0.86