RLS-Based Time Delay Control Method for Distributed Asynchronous Sheath Current Sensing in Underground HV Cable Systems

Distributed sheath current sensing in HV cable systems is vital for grounding fault detection. However, the signal is occasionally lost in underground sensing applications with previous synchronized methods based on satellite time transfer. In this paper, a time delay control method based on parallel Smith estimation and the coupling law between cables via RLS (Recursive Least Square) is proposed for asynchronous sheath current sensing in underground HV cable systems. This method is verified by the field test on the primary side high voltage cable of the traction transformer of 220 kV high-speed railway. The result shows that the proposed method converges to the minimum residual value point, the average residual is 0.321 A, the accurate time delay is 5.22 s, and the synchronization of distributed sheath current sensing can be realized.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3550963
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RLS-Based Time Delay Control Method for Distributed Asynchronous Sheath Current Sensing in Underground HV Cable Systems

Bin Yang, Tu Jing, Yitao Yan, Rui Song et al.
IEEE Access
High-Voltage Power Transmission Systems
article

RLS-Based Time Delay Control Method for Distributed Asynchronous Sheath Current Sensing in Underground HV Cable Systems

Bin Yang, Tu Jing, Yitao Yan, Rui Song, Shasha Zhou, Zhanran Xia, Hang Wang, Long Qiu, Yongheng Ai
article en

Abstract

Distributed sheath current sensing in HV cable systems is vital for grounding fault detection. However, the signal is occasionally lost in underground sensing applications with previous synchronized methods based on satellite time transfer. In this paper, a time delay control method based on parallel Smith estimation and the coupling law between cables via RLS (Recursive Least Square) is proposed for asynchronous sheath current sensing in underground HV cable systems. This method is verified by the field test on the primary side high voltage cable of the traction transformer of 220 kV high-speed railway. The result shows that the proposed method converges to the minimum residual value point, the average residual is 0.321 A, the accurate time delay is 5.22 s, and the synchronization of distributed sheath current sensing can be realized.

IEEE AccessVol. 13
State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN), Economic Research Institute (BG), Hubei University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 96%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RLS-Based Time Delay Control Method for Distributed Asynchronous Sheath Current Sensing in Underground HV Cable Systems — Bin Yang, Tu Jing, et al. · IEEE Access (2025) | TGRS Research Map | TGRS