Air-CLS Detector: A Modified Crosshair Light-Sharing PET Detector With Air Gaps in the U-Shape Light Path

We have developed a crosshair light-sharing (CLS) detector to obtain time-of-flight and depth-of-interaction (DOI) information; the detector consists of a 2-D crystal array with three layers of reflective material, and has a loop structure within a pair of crystal bars. In this work, we modified the detector structure by removing optical glue between the crystals forming the loop structure for the purpose of simplifying the assembly process. The modified CLS was made of fast lutetium-gadolinium oxyorthosilicate (LGSO) crystals with dimensions of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.45\times 1.45\times 15$ </tex-math></inline-formula> mm3 that were optically coupled to the multipixel photon counter (MPPC) array. Most optical windows of the top and bottom layers of the new Air-CLS were so-called air gaps. Only the optical windows that contribute to maintaining the 3-D structure of the reflective material were optically bonded, and a grid of reflective material was formed within the MPPC protective cover. This approach also improved the coincidence resolving time (CRT). The Air-CLSs and previous room temperature vulcanized (RTV)-CLSs were read out by TOFPET2 application-specific integrated circuits, respectively. For Air-CLS (RTV-CLS), we obtained CRT of 188 ps (197 ps), energy resolution of 14.3% (13.1%), and DOI resolution of 3.6 mm (2.9 mm). The Air-CLS significantly simplifies the assembly process while achieving the CRT of less than 190 ps.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-03-14
DOI
https://doi.org/10.1109/trpms.2025.3551520
Citations
3
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air-CLS Detector: A Modified Crosshair Light-Sharing PET Detector With Air Gaps in the U-Shape Light Path

Fujino Obata, Taiga Yamaya, Eiji Yoshida
3 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Medical Imaging Techniques and Applications
4.08
article

Air-CLS Detector: A Modified Crosshair Light-Sharing PET Detector With Air Gaps in the U-Shape Light Path

Fujino Obata, Taiga Yamaya, Eiji Yoshida
article en
3 citations

Abstract

We have developed a crosshair light-sharing (CLS) detector to obtain time-of-flight and depth-of-interaction (DOI) information; the detector consists of a 2-D crystal array with three layers of reflective material, and has a loop structure within a pair of crystal bars. In this work, we modified the detector structure by removing optical glue between the crystals forming the loop structure for the purpose of simplifying the assembly process. The modified CLS was made of fast lutetium-gadolinium oxyorthosilicate (LGSO) crystals with dimensions of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.45\times 1.45\times 15$ </tex-math></inline-formula> mm3 that were optically coupled to the multipixel photon counter (MPPC) array. Most optical windows of the top and bottom layers of the new Air-CLS were so-called air gaps. Only the optical windows that contribute to maintaining the 3-D structure of the reflective material were optically bonded, and a grid of reflective material was formed within the MPPC protective cover. This approach also improved the coincidence resolving time (CRT). The Air-CLSs and previous room temperature vulcanized (RTV)-CLSs were read out by TOFPET2 application-specific integrated circuits, respectively. For Air-CLS (RTV-CLS), we obtained CRT of 188 ps (197 ps), energy resolution of 14.3% (13.1%), and DOI resolution of 3.6 mm (2.9 mm). The Air-CLS significantly simplifies the assembly process while achieving the CRT of less than 190 ps.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(7)
National Institutes for Quantum Science and Technology (JP)
Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering, Japan Society for the Promotion of Science
Openalex Percentile: Top 7%
Medical Imaging Techniques and Applications
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Air-CLS Detector: A Modified Crosshair Light-Sharing PET Detector With Air Gaps in the U-Shape Light Path — Fujino Obata, Taiga Yamaya, et al. · IEEE Transactions on Radiation and Plasma Medical Sciences (2025) | TGRS Research Map | TGRS