Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of <i>N</i>,<i>N</i>-Dimethyltryptamine

A simple and efficient approach that combined electrogenerated chemiluminescence (ECL) and molecularly imprinted polymers (MIPs) for selective and sensitive detection of the hallucinogenic drug <i>N,N</i>-dimethyltryptamine (DMT) was developed. ECL, one of the most sensitive analytical techniques for ultratrace analyte detection, offers the advantage of light-free spectroscopic analysis initiated by electrochemistry. MIPs, on the other hand, provide specific binding sites, allowing the target analyte to become selectively imprinted within the polymer matrix. In this study, an ECL coupled-MIP sensor was fabricated using <i>para</i>-aminobenzoic acid (<i>p</i>-ABA) as the monomer and DMT as the template molecule. The MIP was electropolymerized onto a glassy carbon electrode coated with a Nafion film entrapping [Ru(bpy)<sub>3</sub>]<sup>2+</sup> species. Following elution, the imprinted sites were reoccupied by DMT, generating ECL signals in a phosphate buffered solution during anodic potential scanning. The ECL-MIP sensor demonstrated a wide dynamic range for DMT detection, from 0.5 to 300 μM, with an estimated detection limit of 0.5-1.0 μM (<i>S</i>/<i>N</i> = 3). The sensor's reproducibility, stability, and selectivity were also evaluated. Finally, density functional theory was employed to investigate the structure-property relationship of the <i>p</i>-ABA-DMT interaction. This work demonstrated the potential of ECL coupled with MIP technology for identifying structurally related molecules, achieving enhanced selectivity with a simple and cost-effective design.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-03-14
DOI
https://doi.org/10.1021/acs.analchem.4c06886
Citations
8
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
6.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N,N-Dimethyltryptamine

Karl J. Wallace, Paramasivam Mahalingavelar, Jesy Alka Motchaalangaram, Wujian Miao
8 citations
Analytical Chemistry
Analytical chemistry methods development
6.02
article

Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N,N-Dimethyltryptamine

Karl J. Wallace, Paramasivam Mahalingavelar, Jesy Alka Motchaalangaram, Wujian Miao
article en
8 citations

Abstract

A simple and efficient approach that combined electrogenerated chemiluminescence (ECL) and molecularly imprinted polymers (MIPs) for selective and sensitive detection of the hallucinogenic drug <i>N,N</i>-dimethyltryptamine (DMT) was developed. ECL, one of the most sensitive analytical techniques for ultratrace analyte detection, offers the advantage of light-free spectroscopic analysis initiated by electrochemistry. MIPs, on the other hand, provide specific binding sites, allowing the target analyte to become selectively imprinted within the polymer matrix. In this study, an ECL coupled-MIP sensor was fabricated using <i>para</i>-aminobenzoic acid (<i>p</i>-ABA) as the monomer and DMT as the template molecule. The MIP was electropolymerized onto a glassy carbon electrode coated with a Nafion film entrapping [Ru(bpy)<sub>3</sub>]<sup>2+</sup> species. Following elution, the imprinted sites were reoccupied by DMT, generating ECL signals in a phosphate buffered solution during anodic potential scanning. The ECL-MIP sensor demonstrated a wide dynamic range for DMT detection, from 0.5 to 300 μM, with an estimated detection limit of 0.5-1.0 μM (<i>S</i>/<i>N</i> = 3). The sensor's reproducibility, stability, and selectivity were also evaluated. Finally, density functional theory was employed to investigate the structure-property relationship of the <i>p</i>-ABA-DMT interaction. This work demonstrated the potential of ECL coupled with MIP technology for identifying structurally related molecules, achieving enhanced selectivity with a simple and cost-effective design.

Analytical ChemistryVol. 97(11)
University of Southern Mississippi (US)
U.S. Department of Defense
Openalex Percentile: Top 3%
Analytical chemistry methods development
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of <i>N</i>,<i>N</i>-Dimethyltryptamine — Karl J. Wallace, Paramasivam Mahalingavelar, et al. · Analytical Chemistry (2025) | TGRS Research Map | TGRS