Performance Calculation of Pulse Shape Discrimination Based on Photoelectron Quantity

Abstract Pulse Shape Discrimination (PSD) is a widely used technique in many experimental analysis. In this study, we specifically aimed to assess the effectiveness of PSD in accurately measuring decay time. We measured the decay times of a 0.1 wt% Gd-loaded liquid scintillator (Gd-LS) with 5 vol% Ultimagold-F added when irradiated with neutrons and gamma rays, which were emitted from a Cf-252 radiation source, using a two-exponential decay model. We distinguished between gamma-like events and neutron-like events using the time-of-flight difference. Based on the measured decay times, we developed a simulation to model the waveforms. In the simulation, we adjusted the number of photoelectrons (NPE) and generated waveforms for NPE ranging from 10 to 1000 photoelectrons. We investigated the pulse shape discrimination (PSD) performance as a function of NPE photoelectrons (PE) and determined that at least 49 PE is required for a neutron-like events rejection efficiency of 90%, while keeping gamma-like events 97.8%.

Authors

Institutions

Publication Details

Journal
Progress of Theoretical and Experimental Physics
Published
2025-03-13
DOI
https://doi.org/10.1093/ptep/ptaf042
Citations
1
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Calculation of Pulse Shape Discrimination Based on Photoelectron Quantity

Jae-Sun Park, Seunghyun Hong
1 citations
Progress of Theoretical and Experimental Physics
Advanced Measurement and Detection Methods
0.73
article

Performance Calculation of Pulse Shape Discrimination Based on Photoelectron Quantity

Jae-Sun Park, Seunghyun Hong
article en
1 citations

Abstract

Abstract Pulse Shape Discrimination (PSD) is a widely used technique in many experimental analysis. In this study, we specifically aimed to assess the effectiveness of PSD in accurately measuring decay time. We measured the decay times of a 0.1 wt% Gd-loaded liquid scintillator (Gd-LS) with 5 vol% Ultimagold-F added when irradiated with neutrons and gamma rays, which were emitted from a Cf-252 radiation source, using a two-exponential decay model. We distinguished between gamma-like events and neutron-like events using the time-of-flight difference. Based on the measured decay times, we developed a simulation to model the waveforms. In the simulation, we adjusted the number of photoelectrons (NPE) and generated waveforms for NPE ranging from 10 to 1000 photoelectrons. We investigated the pulse shape discrimination (PSD) performance as a function of NPE photoelectrons (PE) and determined that at least 49 PE is required for a neutron-like events rejection efficiency of 90%, while keeping gamma-like events 97.8%.

Progress of Theoretical and Experimental Physics
Kyungpook National University (KR)
Openalex Percentile: Top 31%
Advanced Measurement and Detection Methods
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Calculation of Pulse Shape Discrimination Based on Photoelectron Quantity — Jae-Sun Park, Seunghyun Hong · Progress of Theoretical and Experimental Physics (2025) | TGRS Research Map | TGRS