Multifrequency measurement system with no frequency ambiguity based on two frequency-space mappings

Multifrequency measurement system with no frequency ambiguity based on two frequency-space mappings has been designed and investigated. By simultaneously mapping the unknown frequencies with a certain frequency shift onto non-flat optical frequency combs (OFCs) and obtaining two beat frequency signals using two balanced photodetectors (BPD), the channel where the measured signal is located can be determined, achieving instantaneous measurement of multifrequencies while effectively addressing five possible types of frequency ambiguity. Simulation results indicate that when the comb line spacing of the OFC is designed as 2 GHz, the measurement range of the system is 0.1 to 30 GHz, with a measurement error within ±1 MHz and a measurement resolution of 2.7 MHz. Furthermore, by adjusting the comb line spacing of the OFC to 4 GHz, the frequency measurement range can be extended to 60 GHz.

Authors

Institutions

Publication Details

Journal
Optical Engineering
Published
2025-03-13
DOI
https://doi.org/10.1117/1.oe.64.3.038104
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
1.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multifrequency measurement system with no frequency ambiguity based on two frequency-space mappings

Jiahong Zhang, Di Ma, Peiqi Li
1 citations
Optical Engineering
Sensor Technology and Measurement Systems
1.49
article

Multifrequency measurement system with no frequency ambiguity based on two frequency-space mappings

Jiahong Zhang, Di Ma, Peiqi Li
article en
1 citations

Abstract

Multifrequency measurement system with no frequency ambiguity based on two frequency-space mappings has been designed and investigated. By simultaneously mapping the unknown frequencies with a certain frequency shift onto non-flat optical frequency combs (OFCs) and obtaining two beat frequency signals using two balanced photodetectors (BPD), the channel where the measured signal is located can be determined, achieving instantaneous measurement of multifrequencies while effectively addressing five possible types of frequency ambiguity. Simulation results indicate that when the comb line spacing of the OFC is designed as 2 GHz, the measurement range of the system is 0.1 to 30 GHz, with a measurement error within ±1 MHz and a measurement resolution of 2.7 MHz. Furthermore, by adjusting the comb line spacing of the OFC to 4 GHz, the frequency measurement range can be extended to 60 GHz.

Optical EngineeringVol. 64(03)
Kunming University of Science and Technology (CN)
Openalex Percentile: Top 19%
Sensor Technology and Measurement Systems
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.