Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments

Methylmercury (CH<sub>3</sub>Hg(I)), produced by the action of aquatic bacteria on inorganic mercury, is the most hazardous among the mercury species. To date, no ratiometric fluorescent probes have been reported for the detection of both CH<sub>3</sub>Hg(I) and Hg(II) in aquatic environments and in live cells. Herein, we designed a novel fluorescent probe incorporating a peptide containing a histidine residue with self-assembly properties specific to both mercury species and a fluorophore that exhibits red-shifted emissions upon aggregation. The probe effectively detected Hg(II) and CH<sub>3</sub>Hg(I) in aqueous solutions (1% DMSO) through ratiometric fluorescence sensing with visible-light excitation (445 nm). The probe exhibited high selectivity for Hg(II) and CH<sub>3</sub>Hg(I) among 19 metal ions, rapid response times (<4 s for CH<sub>3</sub>Hg(I)), low detection limits (12.5 nM for Hg(II) and 248.6 nM for CH<sub>3</sub>Hg(I)), reversible sensing, and a broad operational pH range. As a result, the probe was successfully employed for rapid and real-time sensing of CH<sub>3</sub>Hg(I) and Hg(II) in both aquatic environments and live cells through distinct ratiometric fluorescent changes. A comprehensive binding mode study using dynamic light scattering, IR and CD spectroscopy, and NMR spectroscopy revealed that the chelation of mercury species by the peptide with the metal-binding site and the fluorophore triggers the self-assembly of the complex, enabling fast and sensitive ratiometric detection of mercury species. The combination of a self-assembling peptide with a metal-binding site and a responsive fluorophore provides a valuable fluorescent sensing platform for the detection and quantification of specific analytes, particularly in complex matrices.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-03-13
DOI
https://doi.org/10.1021/acs.analchem.4c05362
Citations
20
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
15.13

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments

Keun‐Hyeung Lee, Sumita Subedi, Heon Joo Park, Eun‐Taex Oh et al.
20 citations
Analytical Chemistry
Molecular Sensors and Ion Detection
15.13
article

Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments

Keun‐Hyeung Lee, Sumita Subedi, Heon Joo Park, Eun‐Taex Oh, Jieun Park, Hyojin Park
article en
20 citations

Abstract

Methylmercury (CH<sub>3</sub>Hg(I)), produced by the action of aquatic bacteria on inorganic mercury, is the most hazardous among the mercury species. To date, no ratiometric fluorescent probes have been reported for the detection of both CH<sub>3</sub>Hg(I) and Hg(II) in aquatic environments and in live cells. Herein, we designed a novel fluorescent probe incorporating a peptide containing a histidine residue with self-assembly properties specific to both mercury species and a fluorophore that exhibits red-shifted emissions upon aggregation. The probe effectively detected Hg(II) and CH<sub>3</sub>Hg(I) in aqueous solutions (1% DMSO) through ratiometric fluorescence sensing with visible-light excitation (445 nm). The probe exhibited high selectivity for Hg(II) and CH<sub>3</sub>Hg(I) among 19 metal ions, rapid response times (<4 s for CH<sub>3</sub>Hg(I)), low detection limits (12.5 nM for Hg(II) and 248.6 nM for CH<sub>3</sub>Hg(I)), reversible sensing, and a broad operational pH range. As a result, the probe was successfully employed for rapid and real-time sensing of CH<sub>3</sub>Hg(I) and Hg(II) in both aquatic environments and live cells through distinct ratiometric fluorescent changes. A comprehensive binding mode study using dynamic light scattering, IR and CD spectroscopy, and NMR spectroscopy revealed that the chelation of mercury species by the peptide with the metal-binding site and the fluorophore triggers the self-assembly of the complex, enabling fast and sensitive ratiometric detection of mercury species. The combination of a self-assembling peptide with a metal-binding site and a responsive fluorophore provides a valuable fluorescent sensing platform for the detection and quantification of specific analytes, particularly in complex matrices.

Analytical ChemistryVol. 97(11)
Inha University (KR), Smart Material (Germany) (DE), Institute of Biomedical Science (GB)
Inha University
Clean water and sanitation
Openalex Percentile: Top 1%
Molecular Sensors and Ion Detection
15.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.