Cycle performance study on cascade high temperature air source heat pump system

Abstract Conventional air source heat pumps face significant challenges in producing hot water above 70°C at an ambient temperature of -30°C. Cascade heat pump systems allow for the utilization of two working fluids within their optimal thermodynamic properties, enabling heating over large temperature rise—exceeding 100°C. This study established a cascade heat pump cycle model, compared the thermal performance of 10 working fluids, and screened a working fluid combination with good thermal performance under the premise of environmental protection and safety. When the low-temperature working fluid is R161 and the high-temperature working fluid is R142b, the coefficient of performance ( COP ) is above 2.14. The variable operating cycle performance of the R161/R142b cascade heat pump was analyzed. The condensing temperature is 40∼70°C, the evaporating temperature is 40∼70°C, and the system COP and compression ratio are both within a reasonable range.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-03-01
DOI
https://doi.org/10.1088/1742-6596/2975/1/012010
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cycle performance study on cascade high temperature air source heat pump system

Rendong Shen, Da Huo
Journal of Physics Conference Series
Heat Transfer and Optimization
article

Cycle performance study on cascade high temperature air source heat pump system

Rendong Shen, Da Huo
article en

Abstract

Abstract Conventional air source heat pumps face significant challenges in producing hot water above 70°C at an ambient temperature of -30°C. Cascade heat pump systems allow for the utilization of two working fluids within their optimal thermodynamic properties, enabling heating over large temperature rise—exceeding 100°C. This study established a cascade heat pump cycle model, compared the thermal performance of 10 working fluids, and screened a working fluid combination with good thermal performance under the premise of environmental protection and safety. When the low-temperature working fluid is R161 and the high-temperature working fluid is R142b, the coefficient of performance ( COP ) is above 2.14. The variable operating cycle performance of the R161/R142b cascade heat pump was analyzed. The condensing temperature is 40∼70°C, the evaporating temperature is 40∼70°C, and the system COP and compression ratio are both within a reasonable range.

Journal of Physics Conference SeriesVol. 2975(1)
Huaneng Clean Energy Research Institute (CN), Zhejiang University of Water Resource and Electric Power (CN)
Openalex Percentile: Top 96%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.