Compact beam position monitor using a segmented toroidal coil

An inductive compact beam position monitor based on a segmented toroidal coil surrounding the charged particle beam has been investigated. It makes use of the induced voltages in the windings instead of the induced charge imbalance on capacitor plates in the popular beam position monitors. We theoretically investigate the response of the coils to the bunched particle beam based on a lumped-element model and compare it to the measurements in the laboratory and in the storage ring COSY in terms of beam displacement. As to the frequency response of the coils, we find a resonant behavior, which may be exploited to further increase the sensitivity of the device. The resolution presently achieved is about 5 μm in a 1 s time interval for a beam current of 0.5 mA.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0240076
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compact beam position monitor using a segmented toroidal coil

Helmut Soltner, J. Pretz, F. Abusaif, F. Trinkel et al.
Review of Scientific Instruments
Particle accelerators and beam dynamics
article

Compact beam position monitor using a segmented toroidal coil

Helmut Soltner, J. Pretz, F. Abusaif, F. Trinkel, A. Nass, Rahul Suvarna, D. Shergelashvili, F. Rathmann, F. Hinder
article en

Abstract

An inductive compact beam position monitor based on a segmented toroidal coil surrounding the charged particle beam has been investigated. It makes use of the induced voltages in the windings instead of the induced charge imbalance on capacitor plates in the popular beam position monitors. We theoretically investigate the response of the coils to the bunched particle beam based on a lumped-element model and compare it to the measurements in the laboratory and in the storage ring COSY in terms of beam displacement. As to the frequency response of the coils, we find a resonant behavior, which may be exploited to further increase the sensitivity of the device. The resolution presently achieved is about 5 μm in a 1 s time interval for a beam current of 0.5 mA.

Review of Scientific InstrumentsVol. 96(3)
Karlsruhe Institute of Technology (DE), Tbilisi State University (GE), GSI Helmholtz Centre for Heavy Ion Research (DE), Forschungszentrum Jülich (DE), Brookhaven National Laboratory (US), Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE), RWTH Aachen University (DE)
European Commission
Affordable and clean energy
Openalex Percentile: Top 94%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Compact beam position monitor using a segmented toroidal coil — Helmut Soltner, J. Pretz, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS