2099 Examining the Relationship Between DTI Tractography and Epilepsy Localization

INTRODUCTION: Epilepsy localization is critical in surgical intervention for patients with drug-resistant epilepsy (DRE). Current presurgical workup may include scalp EEG and stereo EEG, brain MRI, PET, neuropsychological examination, and more to establish localization. However, information from these studies sometimes provides equivocal conclusions. Diffusion tensor images (DTI) with existing magnetic resonance imaging technology measure water diffusion through anisotropy to highlight white matter tracts and could potentially provide additional localization information. METHODS: We obtained and retrospectively analyzed FA values for 17 white matter tracts from the bilateral hemispheres of 73 patients undergoing pre-surgical workup for DRE. The patient’s FA values were calculated using DSI Studio, a tractography software tool for DTI. The laterality of the patient’s epilepsy was determined using the epileptologist’s report in the patient’s chart. A total of 21 patients were excluded because the source of epilepsy was bilateral or unable to be definitively localized by the epileptologist. We compared right and left FA differences for individuals to the standard deviation across the population for each tract. RESULTS: We found the hemisphere with smaller FA values corresponded with the clinically determined epileptic localization 76.8% of the time. Furthermore, when FA value differences between hemispheres were >2.5 standard deviations, the localization accuracy increased to 86.7% of the time. CONCLUSIONS: This study suggests that differences in FA values between hemispheres may provide evidence for laterality localization with smaller FA values indicating a higher likelihood of epileptic onset. Additionally, higher specificity was observed when differences in a given patient were increased.

Authors

Publication Details

Journal
Neurosurgery
Published
2025-03-14
DOI
https://doi.org/10.1227/neu.0000000000003360_2099
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2099 Examining the Relationship Between DTI Tractography and Epilepsy Localization

Patrick Landazuri, Adam G. Rouse, Caleb Pearson, Christopher Y. Park et al.
Neurosurgery
Advanced Neuroimaging Techniques and Applications
article

2099 Examining the Relationship Between DTI Tractography and Epilepsy Localization

Patrick Landazuri, Adam G. Rouse, Caleb Pearson, Christopher Y. Park, Namie N. Fotion, Hannah Judd, McKenzie Rynard
article en

Abstract

INTRODUCTION: Epilepsy localization is critical in surgical intervention for patients with drug-resistant epilepsy (DRE). Current presurgical workup may include scalp EEG and stereo EEG, brain MRI, PET, neuropsychological examination, and more to establish localization. However, information from these studies sometimes provides equivocal conclusions. Diffusion tensor images (DTI) with existing magnetic resonance imaging technology measure water diffusion through anisotropy to highlight white matter tracts and could potentially provide additional localization information. METHODS: We obtained and retrospectively analyzed FA values for 17 white matter tracts from the bilateral hemispheres of 73 patients undergoing pre-surgical workup for DRE. The patient’s FA values were calculated using DSI Studio, a tractography software tool for DTI. The laterality of the patient’s epilepsy was determined using the epileptologist’s report in the patient’s chart. A total of 21 patients were excluded because the source of epilepsy was bilateral or unable to be definitively localized by the epileptologist. We compared right and left FA differences for individuals to the standard deviation across the population for each tract. RESULTS: We found the hemisphere with smaller FA values corresponded with the clinically determined epileptic localization 76.8% of the time. Furthermore, when FA value differences between hemispheres were >2.5 standard deviations, the localization accuracy increased to 86.7% of the time. CONCLUSIONS: This study suggests that differences in FA values between hemispheres may provide evidence for laterality localization with smaller FA values indicating a higher likelihood of epileptic onset. Additionally, higher specificity was observed when differences in a given patient were increased.

NeurosurgeryVol. 71(Supplement_1)
Openalex Percentile: Top 93%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.