1001 Characterizing Depth Electrode Coverage in Stereoelectroencephalography (SEEG) on Seizure Onset Zone Localization and Seizure Outcomes

INTRODUCTION: The number of intracranial depth electrodes implanted in stereoelectroencephalography (SEEG) investigations is primarily driven by the pre-implantation hypothesis about SOZ location. Targeting is not standardized and highly variable between centers. METHODS: We identified a retrospective multi-institutional cohort implanted with depth electrodes for iEEG monitoring between 2001 and 2022. We collected preoperative clinical features and iEEG investigation parameters, including the number of depth electrodes and contacts implanted. We built a propensity matched cohort with respect to these covariates and evaluated outcomes, which included 1) the likelihood of SOZ localization, 2) complications, and 3) seizure free outcomes as a function of electrode contact coverage. In addition, we aimed to identify brain regions commonly explored in conjunction with each other and identify the likelihood of a region being implicated in initial electroclinical seizure onset. RESULTS: One hundred and sixty-seven patients were followed for a median of 3.8 (range 2, 18) years after SEEG. Propensity matched cohorts demonstrated that a higher number of implanted contacts was associated with a greater likelihood of proceeding to treatment, but was not associated with SOZ localization, seizure freedom (Engel I), favorable seizure outcomes (Engel I/II), or complications, per Bayes factor analysis. Lateral orbitofrontal, supramarginal, posterior cingulate, inferior parietal, and inferior temporal areas were least likely to be implicated in initial electrographic onset, whereas hippocampus, caudal middle frontal, pericalcarine, and parahippocampal areas were most likely when controlling for electrode coverage. CONCLUSIONS: SEEG effectively localizes the SOZ in both lesional and non-lesional etiologies, and clinicians are generally optimizing the electrode coverage for hypothetical SOZ localization, leading to further therapeutic surgeries that may confer seizure freedom. Nevertheless, several areas are possibly being explored despite low likelihood (<2.5%) of participation within the SOZ.

Authors

Publication Details

Journal
Neurosurgery
Published
2025-03-14
DOI
https://doi.org/10.1227/neu.0000000000003360_1001
Primary Topic
Functional Brain Connectivity Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1001 Characterizing Depth Electrode Coverage in Stereoelectroencephalography (SEEG) on Seizure Onset Zone Localization and Seizure Outcomes

Aaron E. L. Warren, Pariya Salami, John D. Rolston, S. Sydney Cash et al.
Neurosurgery
Functional Brain Connectivity Studies
article

1001 Characterizing Depth Electrode Coverage in Stereoelectroencephalography (SEEG) on Seizure Onset Zone Localization and Seizure Outcomes

Aaron E. L. Warren, Pariya Salami, John D. Rolston, S. Sydney Cash, Angelique C. Paulk, Noah Nawabi, Rohan Jha
article en

Abstract

INTRODUCTION: The number of intracranial depth electrodes implanted in stereoelectroencephalography (SEEG) investigations is primarily driven by the pre-implantation hypothesis about SOZ location. Targeting is not standardized and highly variable between centers. METHODS: We identified a retrospective multi-institutional cohort implanted with depth electrodes for iEEG monitoring between 2001 and 2022. We collected preoperative clinical features and iEEG investigation parameters, including the number of depth electrodes and contacts implanted. We built a propensity matched cohort with respect to these covariates and evaluated outcomes, which included 1) the likelihood of SOZ localization, 2) complications, and 3) seizure free outcomes as a function of electrode contact coverage. In addition, we aimed to identify brain regions commonly explored in conjunction with each other and identify the likelihood of a region being implicated in initial electroclinical seizure onset. RESULTS: One hundred and sixty-seven patients were followed for a median of 3.8 (range 2, 18) years after SEEG. Propensity matched cohorts demonstrated that a higher number of implanted contacts was associated with a greater likelihood of proceeding to treatment, but was not associated with SOZ localization, seizure freedom (Engel I), favorable seizure outcomes (Engel I/II), or complications, per Bayes factor analysis. Lateral orbitofrontal, supramarginal, posterior cingulate, inferior parietal, and inferior temporal areas were least likely to be implicated in initial electrographic onset, whereas hippocampus, caudal middle frontal, pericalcarine, and parahippocampal areas were most likely when controlling for electrode coverage. CONCLUSIONS: SEEG effectively localizes the SOZ in both lesional and non-lesional etiologies, and clinicians are generally optimizing the electrode coverage for hypothetical SOZ localization, leading to further therapeutic surgeries that may confer seizure freedom. Nevertheless, several areas are possibly being explored despite low likelihood (<2.5%) of participation within the SOZ.

NeurosurgeryVol. 71(Supplement_1)
Openalex Percentile: Top 95%
Functional Brain Connectivity Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.