Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura university children’s hospital laboratories (MUCHLs) using CLIA LIMITS 1988 & 2024

IntroductionAnalytical quality is a crucial prerequisite for best practice in medical laboratory. Six-Sigma Methodology (SM) is a quality measurement tool used to evaluate laboratory performance. This study aims to assess the analytical phase baseline performance using SM and compare results using TEa of CLIA 1988 and CLIA 2024.Materials and methodsCoefficient of variation and bias were determined for 14 analytes. The sigma level for each parameter was calculated using total allowable error (TEa) for CLIA 1988 and CLIA 2024. The quality goal index ratio was calculated for analytes with Sigma less than 3. Normalized method decision Charts were plotted for level 1 and 2 Bio-Rad internal quality control for both CLIA 1988 and 2024.ResultsUsing CLIA TEa 1988, HDL-C, triglycerides & uric acid for level 1 and ALT, AST, HDL-C, calcium, triglycerides & uric acid for level 2 had six Sigma world class performance, meanwhile, only BUN for level 1 and 2 performed less than 3. Using CLIA TEa 2024, HDL-C, GGT, and triglycerides for level 1 and ALT, AST, calcium, GGT, and triglycerides for level 2 had world class quality performance. Meanwhile, creatinine, glucose, BUN for level 1 and BUN and creatinine for level 2 performed less than 3.ConclusionEvaluation of baseline analytical performance using SM revealed lower sigma values with stringent CLIA TEa 2024 versus tolerant CLIA TEa 1988. Improvement in the methodology of analytes with poor performance on some assay platforms with stringent quality control regimes is recommended.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2025-03-14
DOI
https://doi.org/10.1177/00045632251330163
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura university children’s hospital laboratories (MUCHLs) using CLIA LIMITS 1988 & 2024

N.H. Karam, Nessma Ahmed Nosser, Abdel‐Hady El‐Gilany, Reham M. El-Farahaty
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Clinical Laboratory Practices and Quality Control
article

Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura university children’s hospital laboratories (MUCHLs) using CLIA LIMITS 1988 & 2024

N.H. Karam, Nessma Ahmed Nosser, Abdel‐Hady El‐Gilany, Reham M. El-Farahaty
article en

Abstract

IntroductionAnalytical quality is a crucial prerequisite for best practice in medical laboratory. Six-Sigma Methodology (SM) is a quality measurement tool used to evaluate laboratory performance. This study aims to assess the analytical phase baseline performance using SM and compare results using TEa of CLIA 1988 and CLIA 2024.Materials and methodsCoefficient of variation and bias were determined for 14 analytes. The sigma level for each parameter was calculated using total allowable error (TEa) for CLIA 1988 and CLIA 2024. The quality goal index ratio was calculated for analytes with Sigma less than 3. Normalized method decision Charts were plotted for level 1 and 2 Bio-Rad internal quality control for both CLIA 1988 and 2024.ResultsUsing CLIA TEa 1988, HDL-C, triglycerides & uric acid for level 1 and ALT, AST, HDL-C, calcium, triglycerides & uric acid for level 2 had six Sigma world class performance, meanwhile, only BUN for level 1 and 2 performed less than 3. Using CLIA TEa 2024, HDL-C, GGT, and triglycerides for level 1 and ALT, AST, calcium, GGT, and triglycerides for level 2 had world class quality performance. Meanwhile, creatinine, glucose, BUN for level 1 and BUN and creatinine for level 2 performed less than 3.ConclusionEvaluation of baseline analytical performance using SM revealed lower sigma values with stringent CLIA TEa 2024 versus tolerant CLIA TEa 1988. Improvement in the methodology of analytes with poor performance on some assay platforms with stringent quality control regimes is recommended.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 62(6)
Mansoura University (EG)
Openalex Percentile: Top 94%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.