Proposal for a Battery to Evaluate Functional Capacity in Older Adults with Disabilities

The purpose was to design and validate a battery of physical tests, called EFEPD-1.0, adapted to assess functionality in people with disabilities. In addition, we sought to analyze the validity and reliability of this battery both for the total group and differentiated by sex. A total of 43 adults with disabilities (32 women and 11 men) participated (57.11 ± 10.12 years). The battery was composed of five blocks of functionality: neuromuscular, combined actions, acceleration, balance, and cardiovascular. The neuromuscular functionality was measured by the vertical and horizontal jump test using the optical system (Opto Jump Next<sup>®</sup>, Microgate, Bolzano, Italy) as well as the Hand Grip (HG) test using a (5030J1, Jamar<sup>®</sup>, Sammons Preston, Inc, Nottinghamshire, UK) hand dynamometer. The combined actions and balance functionality were assessed with the Time Up and Go (TUG) test, the 30 s Chair Stand (30CTS) test, and the One-Leg Stance (OLS) test measured by a manual stopwatch (HS-80TW-1EF, Casio<sup>®</sup>, Tokyo, Japan). The acceleration functionality was evaluated through 20 m sprints and the 505 change of direction (COD505) test, using the (Microgate, Witty<sup>®</sup>, Bolzano, Italy) photocell system. The cardiovascular functionality was evaluated with the Six-Minute Walking Test (6MWT), where heart rate was monitored using the (Polar Team Sport System<sup>®</sup>, Polar Electro Oy, Kempele, Finland), and additional walking mechanics were recorded with Stryd (Stryd Everest 12 Firmware 1.18 Software 3, Stryd Inc., Boulder, CO, USA). The results showed that the intraclass correlation coefficients (ICCs) ranged from moderate to almost perfect (ICC = 0.65-0.98) between test repetitions. Some tests could significantly differentiate (<i>p</i> < 0.05) men and women, highlighting better neuromuscular capacity in men and better balance in women. The correlations between tests showed significant convergent validity. The Evaluation of Functionality in the Disabled Population (EFEPD-1.0) battery not only consistently measures functional capacities in people with disabilities, but it can also discriminate between different subgroups within this population.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-03-14
DOI
https://doi.org/10.3390/s25061813
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal for a Battery to Evaluate Functional Capacity in Older Adults with Disabilities

Sheila Romero Da Cruz, Javier Yanci, Cristina Granados, Iñaki Llodio et al.
1 citations
Sensors
Muscle activation and electromyography studies
0.67
article

Proposal for a Battery to Evaluate Functional Capacity in Older Adults with Disabilities

Sheila Romero Da Cruz, Javier Yanci, Cristina Granados, Iñaki Llodio, Aitor Iturricastillo, Josu Ascondo, Bingen Marcos-Rivero
article en
1 citations

Abstract

The purpose was to design and validate a battery of physical tests, called EFEPD-1.0, adapted to assess functionality in people with disabilities. In addition, we sought to analyze the validity and reliability of this battery both for the total group and differentiated by sex. A total of 43 adults with disabilities (32 women and 11 men) participated (57.11 ± 10.12 years). The battery was composed of five blocks of functionality: neuromuscular, combined actions, acceleration, balance, and cardiovascular. The neuromuscular functionality was measured by the vertical and horizontal jump test using the optical system (Opto Jump Next<sup>®</sup>, Microgate, Bolzano, Italy) as well as the Hand Grip (HG) test using a (5030J1, Jamar<sup>®</sup>, Sammons Preston, Inc, Nottinghamshire, UK) hand dynamometer. The combined actions and balance functionality were assessed with the Time Up and Go (TUG) test, the 30 s Chair Stand (30CTS) test, and the One-Leg Stance (OLS) test measured by a manual stopwatch (HS-80TW-1EF, Casio<sup>®</sup>, Tokyo, Japan). The acceleration functionality was evaluated through 20 m sprints and the 505 change of direction (COD505) test, using the (Microgate, Witty<sup>®</sup>, Bolzano, Italy) photocell system. The cardiovascular functionality was evaluated with the Six-Minute Walking Test (6MWT), where heart rate was monitored using the (Polar Team Sport System<sup>®</sup>, Polar Electro Oy, Kempele, Finland), and additional walking mechanics were recorded with Stryd (Stryd Everest 12 Firmware 1.18 Software 3, Stryd Inc., Boulder, CO, USA). The results showed that the intraclass correlation coefficients (ICCs) ranged from moderate to almost perfect (ICC = 0.65-0.98) between test repetitions. Some tests could significantly differentiate (<i>p</i> < 0.05) men and women, highlighting better neuromuscular capacity in men and better balance in women. The correlations between tests showed significant convergent validity. The Evaluation of Functionality in the Disabled Population (EFEPD-1.0) battery not only consistently measures functional capacities in people with disabilities, but it can also discriminate between different subgroups within this population.

SensorsVol. 25(6)
Ikerbasque (ES), University of the Basque Country (ES), BioCruces Health research Institute (ES)
Quality Education
Openalex Percentile: Top 34%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.