Augmented reality simulation framework for minimally invasive orthopedic surgery

System validation involved analysis at different framework levels. From texture analysis of acquired images to application accuracy evaluation, the influence of various parameters on system performance is demonstrated. The simulation system is a valuable tool for learning minimally invasive procedures and for developers building AR systems for medical applications. The implementation is focused on the insertion surgical devices, including screws and K-wires. This is results in real application in minimizing the risk of iatrogenic injury to neural and vascular structures. To demonstrate the effectiveness of highly reproducible accuracy between real and virtual environment an analysis of errors and accuracies is illustrated at level of different subsystems. Measurement between comparative measurement between vernier caliper and simulation system methods shows a R>0.9 with a p<0.01. Application accuracy was evaluated using the following parameters. The relative point-to-point accuracy averaged 1.02mm with a standard deviation of 2.82mm. Future development includes clinical implementation and integration of advanced AI technologies.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-03-14
DOI
https://doi.org/10.1016/j.compbiomed.2025.109943
Citations
8
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
10.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Augmented reality simulation framework for minimally invasive orthopedic surgery

Paolo Titolo, Marco Agus, Corrado Calı, Massimo Salvi et al.
8 citations
Computers in Biology and Medicine
Augmented Reality Applications
10.21
article

Augmented reality simulation framework for minimally invasive orthopedic surgery

Paolo Titolo, Marco Agus, Corrado Calı, Massimo Salvi, Filippo Molinari, Enrico Vezzetti, Luca Ulrich, Antonio Cangelosi, Giacomo Riberi
article en
8 citations

Abstract

System validation involved analysis at different framework levels. From texture analysis of acquired images to application accuracy evaluation, the influence of various parameters on system performance is demonstrated. The simulation system is a valuable tool for learning minimally invasive procedures and for developers building AR systems for medical applications. The implementation is focused on the insertion surgical devices, including screws and K-wires. This is results in real application in minimizing the risk of iatrogenic injury to neural and vascular structures. To demonstrate the effectiveness of highly reproducible accuracy between real and virtual environment an analysis of errors and accuracies is illustrated at level of different subsystems. Measurement between comparative measurement between vernier caliper and simulation system methods shows a R>0.9 with a p<0.01. Application accuracy was evaluated using the following parameters. The relative point-to-point accuracy averaged 1.02mm with a standard deviation of 2.82mm. Future development includes clinical implementation and integration of advanced AI technologies.

Computers in Biology and MedicineVol. 189
Politecnico di Torino (IT), CTO Hospital (IT), Azienda Ospedaliera Citta' della Salute e della Scienza di Torino (IT), Neuroscience Institute (IT), Hamad bin Khalifa University (QA), University of Turin (IT)
Ministero dell’Istruzione, dell’Università e della Ricerca, Università degli Studi di Torino
Openalex Percentile: Top 2%
Augmented Reality Applications
10.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.