Nonenzymatic Yarn Sensor for Glucose Monitoring

This paper reports the design, fabrication and characterization of a flexible yarn-based nonenzymatic glucose sensor with three-electrode test configuration. The proposed sensor was implemented with three pieces of functional yarn as working, reference and counter electrode. The WE was a copper oxide and activated carbon-coated copper yarn, the RE and CE were glassy carbon-coated copper yarn. The proposed nonenzymatic glucose sensor achieved a sensitivity of 247.6 μA. mM<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup>.cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> for glucose concentrations between 0.1 mM and 8 mM.

Authors

Institutions

Publication Details

Published
2024-11-19
DOI
https://doi.org/10.23919/e-textiles63767.2024.10914163
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonenzymatic Yarn Sensor for Glucose Monitoring

Steve Beeby, Sheng Yong, Daniela Iacopino, Hassan Hamidi et al.
1 citations
Electrochemical sensors and biosensors
0.21
article

Nonenzymatic Yarn Sensor for Glucose Monitoring

Steve Beeby, Sheng Yong, Daniela Iacopino, Hassan Hamidi, Shoufeng Yang, Jidong Liu
article en
1 citations

Abstract

This paper reports the design, fabrication and characterization of a flexible yarn-based nonenzymatic glucose sensor with three-electrode test configuration. The proposed sensor was implemented with three pieces of functional yarn as working, reference and counter electrode. The WE was a copper oxide and activated carbon-coated copper yarn, the RE and CE were glassy carbon-coated copper yarn. The proposed nonenzymatic glucose sensor achieved a sensitivity of 247.6 μA. mM<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup>.cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−2</sup> for glucose concentrations between 0.1 mM and 8 mM.

University College Cork (IE), University of Southampton (GB)
Openalex Percentile: Top 43%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nonenzymatic Yarn Sensor for Glucose Monitoring — Steve Beeby, Sheng Yong, et al. · (2024) | TGRS Research Map | TGRS