An Extremely Low Ripple High-Voltage DC Power Supply System for Depressed Collector Traveling-Wave Tubes

This article investigates the impact of isolating transformer stray capacitances on the output voltage ripple of the high-voltage dc power supply system used in depressed collector traveling-wave tubes (TWTs). It is shown that the common-mode (CM) capacitive current from the isolating transformer of the TWT’s depressed collector power supply passes through the output of the TWT’s cathode power supply. Therefore, an additional ripple is generated at the output of the cathode power supply. In high-voltage applications, adding filters to reduce ripple conflicts with the protection considerations of the load and the power supply. This study focuses on reducing this extra voltage ripple without adding new filters. An analysis is presented to demonstrate the relationship between the voltage ripple of the TWT’s cathode power supply and the stray capacitances of the isolating transformer. A transformer winding structure is then proposed to eliminate the CM capacitive current of the collector power supply. Simulation and experimental results show that using the proposed transformer winding structure leads to a 90% voltage ripple amplitude reduction at the cathode power supply output.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Plasma Science
Published
2025-03-14
DOI
https://doi.org/10.1109/tps.2025.3545136
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Extremely Low Ripple High-Voltage DC Power Supply System for Depressed Collector Traveling-Wave Tubes

Mojtaba Ziaoddini, Shahriyar Kaboli
IEEE Transactions on Plasma Science
HVDC Systems and Fault Protection
article

An Extremely Low Ripple High-Voltage DC Power Supply System for Depressed Collector Traveling-Wave Tubes

Mojtaba Ziaoddini, Shahriyar Kaboli
article en

Abstract

This article investigates the impact of isolating transformer stray capacitances on the output voltage ripple of the high-voltage dc power supply system used in depressed collector traveling-wave tubes (TWTs). It is shown that the common-mode (CM) capacitive current from the isolating transformer of the TWT’s depressed collector power supply passes through the output of the TWT’s cathode power supply. Therefore, an additional ripple is generated at the output of the cathode power supply. In high-voltage applications, adding filters to reduce ripple conflicts with the protection considerations of the load and the power supply. This study focuses on reducing this extra voltage ripple without adding new filters. An analysis is presented to demonstrate the relationship between the voltage ripple of the TWT’s cathode power supply and the stray capacitances of the isolating transformer. A transformer winding structure is then proposed to eliminate the CM capacitive current of the collector power supply. Simulation and experimental results show that using the proposed transformer winding structure leads to a 90% voltage ripple amplitude reduction at the cathode power supply output.

IEEE Transactions on Plasma ScienceVol. 53(4)
Sharif University of Technology (IR)
Affordable and clean energy
Openalex Percentile: Top 96%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.