An Innovative Approach to Accelerate Maxillary Canine Retraction With Low-Amperage Direct Electric Current: A Preliminary Clinical Study

Background and objective Accelerating orthodontic tooth movement is a significant goal for clinicians and patients. This study aimed to investigate the effectiveness of a low-ampere, electrically inducible tooth movement accelerator device. The study focuses on an innovative intraoral removable device designed to expedite the retraction of maxillary canines. Methods This research was conducted in the Orthodontics Department at Damascus University, Syria, between September 2022 and March 2023, and involved seven patients (five females and two males; mean age: 20.85 ± 1.34 years) initially diagnosed with class II, division I malocclusion. The treatment plan included retraction of the upper anterior teeth in two stages following the extraction of the first premolars on each side. Electrical stimulation was applied during the retraction of the maxillary canines using a removable, custom-manufactured device developed by the researchers. Patients were instructed to wear the device for five hours daily. The variables investigated included the rate of canine retraction, safety, and patient acceptance of the device. Results The average rate of canine retraction was consistent, averaging 1.25 ± 0.13 mm/month. No side effects, such as irritation or discomfort, were observed. Patients reported no adverse effects and stated that they would recommend the technique to others. Five out of seven patients found it easy to adapt to the device, while two found it moderately challenging. Conclusions Our findings showed that low-amperage direct current electrical stimulation effectively accelerated orthodontic movement. The maxillary canine retraction was significantly sped up without any adverse effects. Patients responded positively, indicating feasibility and acceptability. This technique could reduce treatment duration, which is pending further validation.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-14
DOI
https://doi.org/10.7759/cureus.80573
Citations
3
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
5.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Innovative Approach to Accelerate Maxillary Canine Retraction With Low-Amperage Direct Electric Current: A Preliminary Clinical Study

Mhd Firas Al Hinnawi, Ahmad Sharafeddin Burhan, Mohammad Younis Hajeer, Samer T. Jaber et al.
3 citations
Cureus
Orthodontics and Dentofacial Orthopedics
5.03
article

An Innovative Approach to Accelerate Maxillary Canine Retraction With Low-Amperage Direct Electric Current: A Preliminary Clinical Study

Mhd Firas Al Hinnawi, Ahmad Sharafeddin Burhan, Mohammad Younis Hajeer, Samer T. Jaber, Mowaffak A Ajaj, Mohammad N Kheshfeh
article en
3 citations

Abstract

Background and objective Accelerating orthodontic tooth movement is a significant goal for clinicians and patients. This study aimed to investigate the effectiveness of a low-ampere, electrically inducible tooth movement accelerator device. The study focuses on an innovative intraoral removable device designed to expedite the retraction of maxillary canines. Methods This research was conducted in the Orthodontics Department at Damascus University, Syria, between September 2022 and March 2023, and involved seven patients (five females and two males; mean age: 20.85 ± 1.34 years) initially diagnosed with class II, division I malocclusion. The treatment plan included retraction of the upper anterior teeth in two stages following the extraction of the first premolars on each side. Electrical stimulation was applied during the retraction of the maxillary canines using a removable, custom-manufactured device developed by the researchers. Patients were instructed to wear the device for five hours daily. The variables investigated included the rate of canine retraction, safety, and patient acceptance of the device. Results The average rate of canine retraction was consistent, averaging 1.25 ± 0.13 mm/month. No side effects, such as irritation or discomfort, were observed. Patients reported no adverse effects and stated that they would recommend the technique to others. Five out of seven patients found it easy to adapt to the device, while two found it moderately challenging. Conclusions Our findings showed that low-amperage direct current electrical stimulation effectively accelerated orthodontic movement. The maxillary canine retraction was significantly sped up without any adverse effects. Patients responded positively, indicating feasibility and acceptability. This technique could reduce treatment duration, which is pending further validation.

CureusVol. 17(3)
Damascus University (SY)
Affordable and clean energy
Openalex Percentile: Top 6%
Orthodontics and Dentofacial Orthopedics
5.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.