An Optimization-based Non-contact Transient Voltage Measurement Method by Integrated Optical Electric Field Sensor

Transient overvoltage in power systems, caused by lightning or switching, are a critical reliability constraint. Traditional contact measurement methods have limitations, prompting the development of non-contact measurement technologies. Integrated Optical Electric Field Sensor (IOES), based on Pockels effects, offers broad advantages for non-contact voltage measurement. This paper introduces an optimization-based decoupling method for multi-phase coupling scenarios in power system such as three-phase transmission lines and verifies its correctness with a non-contact transient voltage measurement system using IOES. The method involves obtaining a simulation decoupling matrix and then finding the “closest” matrix under constraints using optimization techniques. The decoupling results by the optimization-based method outperformed the simulation method in accuracy, demonstrating the effectiveness of the proposed method for non-contact voltage measurement in AC power systems.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/sgei63936.2024.10914209
Primary Topic
Magneto-Optical Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Optimization-based Non-contact Transient Voltage Measurement Method by Integrated Optical Electric Field Sensor

Tianxi Xie, Huaiyuan Yang, Yi-Fei Sun, Bo Qian et al.
Magneto-Optical Properties and Applications
article

An Optimization-based Non-contact Transient Voltage Measurement Method by Integrated Optical Electric Field Sensor

Tianxi Xie, Huaiyuan Yang, Yi-Fei Sun, Bo Qian, Xu Yang, Yang Chen
article en

Abstract

Transient overvoltage in power systems, caused by lightning or switching, are a critical reliability constraint. Traditional contact measurement methods have limitations, prompting the development of non-contact measurement technologies. Integrated Optical Electric Field Sensor (IOES), based on Pockels effects, offers broad advantages for non-contact voltage measurement. This paper introduces an optimization-based decoupling method for multi-phase coupling scenarios in power system such as three-phase transmission lines and verifies its correctness with a non-contact transient voltage measurement system using IOES. The method involves obtaining a simulation decoupling matrix and then finding the “closest” matrix under constraints using optimization techniques. The decoupling results by the optimization-based method outperformed the simulation method in accuracy, demonstrating the effectiveness of the proposed method for non-contact voltage measurement in AC power systems.

Shanghai Electric (China) (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 74%
Magneto-Optical Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.