Speckle Denoising of Dynamic Contrast- Enhanced Ultrasound Using Low-Rank Tensor Decomposition

Dynamic contrast-enhanced ultrasound (DCEUS) is an imaging modality for assessing micro- vascular perfusion and dispersion kinetics. However, the presence of speckle noise may hamper the quantitative analysis of the contrast kinetics. Common speckle denoising techniques based on low-rank approximations typically model the speckle noise as white Gaussian noise (WGN) after the log transformation and apply matrix-based algorithms. We address the high dimensionality of the 4D DCEUS data and apply low-rank tensor decomposition techniques to denoise speckles. Although there are many tensor decompositions that can describe low rankness, we limit our research to multilinear rank and tubal rank. We introduce a gradient-based extension of the multilinear singular value decomposition to model low multilinear rankness, assuming that the log-transformed speckle noise follows a Fisher-tippet distribution. In addition, we apply an algorithm based on tensor singular value decomposition to model low tubal rankness, assuming that the log-transformed speckle noise is WGN with sparse outliers. The effectiveness of the methods is evaluated through simulations and phantom studies. Additionally, the tensor-based algorithms' real-world performance is assessed using DCEUS prostate recordings. Comparative analyses with existing DCEUS denoising literature are conducted, and the algorithms' capabilities are showcased in the context of prostate cancer classification. The addition of Fisher-tippet distribution did not improve the results of tr-MLSVD in the in vivo case. However, most cancer markers are better distinguishable when using a tensor denoising technique than state-of-the-art approaches.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-03-14
DOI
https://doi.org/10.1109/tmi.2025.3551660
Citations
2
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
2.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Speckle Denoising of Dynamic Contrast- Enhanced Ultrasound Using Low-Rank Tensor Decomposition

Metin Calis, A. van Veen, Borbála Hunyadi, Massimo Mischi
2 citations
IEEE Transactions on Medical Imaging
Image and Signal Denoising Methods
2.55
article

Speckle Denoising of Dynamic Contrast- Enhanced Ultrasound Using Low-Rank Tensor Decomposition

Metin Calis, A. van Veen, Borbála Hunyadi, Massimo Mischi
article en
2 citations

Abstract

Dynamic contrast-enhanced ultrasound (DCEUS) is an imaging modality for assessing micro- vascular perfusion and dispersion kinetics. However, the presence of speckle noise may hamper the quantitative analysis of the contrast kinetics. Common speckle denoising techniques based on low-rank approximations typically model the speckle noise as white Gaussian noise (WGN) after the log transformation and apply matrix-based algorithms. We address the high dimensionality of the 4D DCEUS data and apply low-rank tensor decomposition techniques to denoise speckles. Although there are many tensor decompositions that can describe low rankness, we limit our research to multilinear rank and tubal rank. We introduce a gradient-based extension of the multilinear singular value decomposition to model low multilinear rankness, assuming that the log-transformed speckle noise follows a Fisher-tippet distribution. In addition, we apply an algorithm based on tensor singular value decomposition to model low tubal rankness, assuming that the log-transformed speckle noise is WGN with sparse outliers. The effectiveness of the methods is evaluated through simulations and phantom studies. Additionally, the tensor-based algorithms' real-world performance is assessed using DCEUS prostate recordings. Comparative analyses with existing DCEUS denoising literature are conducted, and the algorithms' capabilities are showcased in the context of prostate cancer classification. The addition of Fisher-tippet distribution did not improve the results of tr-MLSVD in the in vivo case. However, most cancer markers are better distinguishable when using a tensor denoising technique than state-of-the-art approaches.

IEEE Transactions on Medical ImagingVol. 44(7)
Eindhoven University of Technology (NL), Delft University of Technology (NL)
Climate action
Openalex Percentile: Top 12%
Image and Signal Denoising Methods
2.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.