Research on the Detection Technology for Scale Layer on Equalizing Electrode in the Converter Valve Cooling System Based on Optical Method

The equalizing electrode is a key component of the converter valve. Aiming at the problem of monitoring the fouling conditions of them, a non-contact detection method based on the infrared light transmittance characteristics of polyvinylidene fluoride (PVDF) material is proposed. By screening the suitable infrared wavelength (940 nm), an infrared optical detection device integrating light source control, optical imaging, and image processing modules was designed. The device adopts a 45-degree reflector and a compact structure design, which improves the flexibility and applicability in limited spaces. During the annual inspection of Baoji Converter Station, a field detection validation was conducted, achieving a test accuracy of 0.1 mm with an error controlled within $\pm 5 \%$.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/sgei63936.2024.10914063
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Detection Technology for Scale Layer on Equalizing Electrode in the Converter Valve Cooling System Based on Optical Method

Wenjin Song, De Ding, Lei Liu, Jingyi Guo et al.
Advanced Sensor and Control Systems
article

Research on the Detection Technology for Scale Layer on Equalizing Electrode in the Converter Valve Cooling System Based on Optical Method

Wenjin Song, De Ding, Lei Liu, Jingyi Guo, Wu Yu
article en

Abstract

The equalizing electrode is a key component of the converter valve. Aiming at the problem of monitoring the fouling conditions of them, a non-contact detection method based on the infrared light transmittance characteristics of polyvinylidene fluoride (PVDF) material is proposed. By screening the suitable infrared wavelength (940 nm), an infrared optical detection device integrating light source control, optical imaging, and image processing modules was designed. The device adopts a 45-degree reflector and a compact structure design, which improves the flexibility and applicability in limited spaces. During the annual inspection of Baoji Converter Station, a field detection validation was conducted, achieving a test accuracy of 0.1 mm with an error controlled within $\pm 5 \%$.

China XD Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 65%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.