Investigating Structural and Positional Impact on ECG Signal Quality of Knitted Active Electrodes for Real Time Healthcare Monitoring

Heart disease is the leading cause of death globally, often going undetected without hospital intervention. Wearable heart rate monitoring (ECG) devices are essential to reduce this problem and provide an efficient and user-friendly means of monitoring the wearer throughout their daily life. This paper investigated the impact on the position and fabrication structure of these wearable electrodes on the electrical quality of the ECG signal. The electrodes were fabricated using a 12-gauge Shima Seiki SES122-S flatbed knitting machine and combined with flexible miniaturised buffer amplifier circuits linked with the electrode to create ‘active’ electrodes that help improve the signal to noise ratio (SNR). Three placement positions for the electrodes were investigated (2 chest positions (horizontal and vertical) and 1 waist) and the position of the amplifier relative to the electrodes (1, 10, 20 cm) was adjusted to identify the optimum SNR representing the effect of electronics positioning relative to the electrodes. The vertical chest position provided the optimal SNR (21.27 dB), a factor of 4 improvement compared to previous results.

Authors

Institutions

Publication Details

Published
2024-11-19
DOI
https://doi.org/10.23919/e-textiles63767.2024.10914199
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating Structural and Positional Impact on ECG Signal Quality of Knitted Active Electrodes for Real Time Healthcare Monitoring

Russel Torah, Atanas Todorov, Kai Yang, Kate Jopling et al.
Ergonomics and Musculoskeletal Disorders
article

Investigating Structural and Positional Impact on ECG Signal Quality of Knitted Active Electrodes for Real Time Healthcare Monitoring

Russel Torah, Atanas Todorov, Kai Yang, Kate Jopling, Thomas Greig
article en

Abstract

Heart disease is the leading cause of death globally, often going undetected without hospital intervention. Wearable heart rate monitoring (ECG) devices are essential to reduce this problem and provide an efficient and user-friendly means of monitoring the wearer throughout their daily life. This paper investigated the impact on the position and fabrication structure of these wearable electrodes on the electrical quality of the ECG signal. The electrodes were fabricated using a 12-gauge Shima Seiki SES122-S flatbed knitting machine and combined with flexible miniaturised buffer amplifier circuits linked with the electrode to create ‘active’ electrodes that help improve the signal to noise ratio (SNR). Three placement positions for the electrodes were investigated (2 chest positions (horizontal and vertical) and 1 waist) and the position of the amplifier relative to the electrodes (1, 10, 20 cm) was adjusted to identify the optimum SNR representing the effect of electronics positioning relative to the electrodes. The vertical chest position provided the optimal SNR (21.27 dB), a factor of 4 improvement compared to previous results.

University of Winchester (GB), University of Southampton (GB)
Openalex Percentile: Top 64%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigating Structural and Positional Impact on ECG Signal Quality of Knitted Active Electrodes for Real Time Healthcare Monitoring — Russel Torah, Atanas Todorov, et al. · (2024) | TGRS Research Map | TGRS