Research on oilfield distributed energy efficiency evaluation and mode based on energy flow

This paper selected the independent generation conditions of the generator set as a reference, and studied the energy efficiency under different utilization modes of distributed energy according to the comparable performance coefficient (CCOP). The results showed that for cooling condition, according to the CCOP, the different cooling methods can be sorted as following: hot water absorption unit > steam absorption unit > direct-fired unit > air conditioner. However, according to the traditional COP, it was air conditioner > direct-fired unit > steam absorption unit > hot water absorption unit. The phenomenon was caused by ignoring the cascade utilization of energy in traditional utilization mode. For heating condition, the results obtained by CCOP and COP was in consistent, presenting hot water absorption unit > steam absorption unit > air conditioner > direct-fired unit. Therefore, whether operating under cooling or heating conditions, the CCOP of direct-fired unit and air conditioner was basically the same, and the traditional COP was not much different. On the other hand, the sorting results obtained by CCOP in heating mode are the same as the traditional method, which proved the effectiveness of this method.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/sgei63936.2024.10914094
Primary Topic
Global Energy and Sustainability Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on oilfield distributed energy efficiency evaluation and mode based on energy flow

Zhao Li, Meng Ke Li, Xingchang Xue, Chao Zhang et al.
Global Energy and Sustainability Research
article

Research on oilfield distributed energy efficiency evaluation and mode based on energy flow

Zhao Li, Meng Ke Li, Xingchang Xue, Chao Zhang, Rong Ying, Peng Qu, Yusong Zhu, Lingwei Ran
article en

Abstract

This paper selected the independent generation conditions of the generator set as a reference, and studied the energy efficiency under different utilization modes of distributed energy according to the comparable performance coefficient (CCOP). The results showed that for cooling condition, according to the CCOP, the different cooling methods can be sorted as following: hot water absorption unit > steam absorption unit > direct-fired unit > air conditioner. However, according to the traditional COP, it was air conditioner > direct-fired unit > steam absorption unit > hot water absorption unit. The phenomenon was caused by ignoring the cascade utilization of energy in traditional utilization mode. For heating condition, the results obtained by CCOP and COP was in consistent, presenting hot water absorption unit > steam absorption unit > air conditioner > direct-fired unit. Therefore, whether operating under cooling or heating conditions, the CCOP of direct-fired unit and air conditioner was basically the same, and the traditional COP was not much different. On the other hand, the sorting results obtained by CCOP in heating mode are the same as the traditional method, which proved the effectiveness of this method.

Karamay Central Hospital of Xinjiang (CN)
Affordable and clean energy
Openalex Percentile: Top 83%
Global Energy and Sustainability Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.