Application of TOPAS in dose calculations of low energy X-ray therapy machines

TOPAS (TOol for PArticle Simulation) is a Monte Carlo tool initially designed for simulating proton therapy machines. This study aims to investigate TOPAS’s applicability and accuracy in simulating orthovoltage therapy machine. An Xstrahl 300 orthovoltage machine was simulated. Spectra, HVLs (Half Value Layers), PDDs (Percentage Depth Doses), dose profiles, and backscatter factors were calculated for 100, 180, and 300 kVp. In addition, 3D (Three-Dimensional) dose distributions on a cranial CT (Computed Tomography) were assessed for a 5 cm diameter field size in different treatment locations. Where applicable, comparisons against other measurements or calculations are presented. ”TrackLengthEstimator” method was employed to investigate the dose distributions in regions of interest. Spectra, except for fluorescent peaks, agree with SpekPy (An X-ray spectrum calculator) calculations. HVLs, PDDs, and dose profiles show agreement with clinical measurements. Backscatter factors for four field sizes (1, 3, 5, and 10 cm diameter) and all energies show agreement (difference <2%) with published data. Visualization of dose distributions and DVHs (Dose Volume Histograms) on clinical CT sets are accessible functionalities. TOPAS is a robust Monte Carlo simulation tool for simulations of an orthovoltage treatment unit and could allow accessible visualization of 3D dose distributions in clinical plans. • Orthovoltage unit is characterized using TOPAS simulation tool. • TOPAS is employed to study the dose in a patient. • TOPAS results are verified by measurement or another Monte Carlo method. • This work explores TOPAS capability for in-house orthovoltage treatment planning.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2025-03-14
DOI
https://doi.org/10.1016/j.radmeas.2025.107415
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of TOPAS in dose calculations of low energy X-ray therapy machines

Thalat Monajemi, S. Ahmadi
2 citations
Radiation Measurements
Advanced Radiotherapy Techniques
3.77
article

Application of TOPAS in dose calculations of low energy X-ray therapy machines

Thalat Monajemi, S. Ahmadi
article en
2 citations

Abstract

TOPAS (TOol for PArticle Simulation) is a Monte Carlo tool initially designed for simulating proton therapy machines. This study aims to investigate TOPAS’s applicability and accuracy in simulating orthovoltage therapy machine. An Xstrahl 300 orthovoltage machine was simulated. Spectra, HVLs (Half Value Layers), PDDs (Percentage Depth Doses), dose profiles, and backscatter factors were calculated for 100, 180, and 300 kVp. In addition, 3D (Three-Dimensional) dose distributions on a cranial CT (Computed Tomography) were assessed for a 5 cm diameter field size in different treatment locations. Where applicable, comparisons against other measurements or calculations are presented. ”TrackLengthEstimator” method was employed to investigate the dose distributions in regions of interest. Spectra, except for fluorescent peaks, agree with SpekPy (An X-ray spectrum calculator) calculations. HVLs, PDDs, and dose profiles show agreement with clinical measurements. Backscatter factors for four field sizes (1, 3, 5, and 10 cm diameter) and all energies show agreement (difference <2%) with published data. Visualization of dose distributions and DVHs (Dose Volume Histograms) on clinical CT sets are accessible functionalities. TOPAS is a robust Monte Carlo simulation tool for simulations of an orthovoltage treatment unit and could allow accessible visualization of 3D dose distributions in clinical plans. • Orthovoltage unit is characterized using TOPAS simulation tool. • TOPAS is employed to study the dose in a patient. • TOPAS results are verified by measurement or another Monte Carlo method. • This work explores TOPAS capability for in-house orthovoltage treatment planning.

Radiation MeasurementsVol. 183
Dalhousie University (CA)
Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 9%
Advanced Radiotherapy Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.