Numerical Investigation on Current Behaviors of NI Multi-Tape-Bundled REBCO Coils Wound With Dump Resistance for Sudden Discharge Test

Progress in the field of applied superconductivity, such as MRI, NMR, and compact fusion reactors, relies on improvements in material developments and winding techniques. The no-insulation (NI) winding technique enables rare-earth barium copper oxide (REBCO) coils to show high electromagnetic characteristics, while having a high current density. The multi-tape-bundled winding technique improves charging delays on large-scale NI REBCO coils. Meanwhile, previous research has suggested several disadvantages of these techniques. Especially in the NI multi-tape-bundled REBCO coils, rapid discharging is reported due to the influence of a small coil inductance, which makes coil protection harder. In this paper, several D-shaped multi-tape-bundled REBCO coils with dump resistor are modeled. Sudden discharging tests are simulated for each model with a different number of bundled tapes and turn-to-turn contact resistivities. The simulation results show that REBCO-tape-longitudinal currents are concentrated on one side, meanwhile the opposite-directional currents are observed on the other side. The concentration is larger as the number of bundled tapes increases. In addition, the Joule heat simulation shows that the energy stored in a coil is discharged faster on the more-tapes-bundled NI REBCO coil, although the energy extracted into the dump resistor is smaller due to the low turn-to-turn/tape-to-tape contact resistance. Further investigations will be needed, especially for a thermal simulation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2025-03-14
DOI
https://doi.org/10.1109/tasc.2025.3551215
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation on Current Behaviors of NI Multi-Tape-Bundled REBCO Coils Wound With Dump Resistance for Sudden Discharge Test

Takanobu Mato, So Noguchi, T. Obana, Haru Sato
3 links
IEEE Transactions on Applied Superconductivity
HVDC Systems and Fault Protection
article

Numerical Investigation on Current Behaviors of NI Multi-Tape-Bundled REBCO Coils Wound With Dump Resistance for Sudden Discharge Test

Takanobu Mato, So Noguchi, T. Obana, Haru Sato
article en

Abstract

Progress in the field of applied superconductivity, such as MRI, NMR, and compact fusion reactors, relies on improvements in material developments and winding techniques. The no-insulation (NI) winding technique enables rare-earth barium copper oxide (REBCO) coils to show high electromagnetic characteristics, while having a high current density. The multi-tape-bundled winding technique improves charging delays on large-scale NI REBCO coils. Meanwhile, previous research has suggested several disadvantages of these techniques. Especially in the NI multi-tape-bundled REBCO coils, rapid discharging is reported due to the influence of a small coil inductance, which makes coil protection harder. In this paper, several D-shaped multi-tape-bundled REBCO coils with dump resistor are modeled. Sudden discharging tests are simulated for each model with a different number of bundled tapes and turn-to-turn contact resistivities. The simulation results show that REBCO-tape-longitudinal currents are concentrated on one side, meanwhile the opposite-directional currents are observed on the other side. The concentration is larger as the number of bundled tapes increases. In addition, the Joule heat simulation shows that the energy stored in a coil is discharged faster on the more-tapes-bundled NI REBCO coil, although the energy extracted into the dump resistor is smaller due to the low turn-to-turn/tape-to-tape contact resistance. Further investigations will be needed, especially for a thermal simulation.

IEEE Transactions on Applied SuperconductivityVol. 35(5)
Hokkaido University (JP), National Institute for Fusion Science (JP)
Openalex Percentile: Top 96%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.