Ubicon-BP: Towards Ubiquitous, Contactless Blood Pressure Detection Using Smartphone

Blood pressure (BP) is a critical physiological parameter closely associated with severe diseases such as heart failure and kidney damage. Current methods either require additional or dedicated hardware, or closing touching to the devices, causing discomfort and inconvenience. Therefore, a convenient, contactless BP measurement solution is highly desired. In this work, we present Ubicon-BP, a ubiquitous, device-free, and contactless BP detection application. Ubicon-BP calculates BP based on the pulse transit time (PTT), a key feature that is medically proven correlated with BP. However, using smartphone sensors to contactless calculate PTT is non-trivial since it requires a micro-second level precision for cardiac event detection. To address this issue, we propose leveraging the acoustic sensors in smartphone to detect vibrations caused by heart valve movements, as well as camera sensors to measure finger pulses. To accurately measure heartbeat signal that are susceptible to motion, we first improve the sensing granularity of acoustic signals and then introduce the IQ-MVED model to eliminate motion interference. Furthermore, when recovering pulse signals from video signals, issues such as poor generalization performance arise. Consequently, we propose the TS-CAN and meta-learning models to obtain personalized pulse signals. Finally, we transform the extracted time-frequency features from the recovered heartbeats and pulse signals to the corresponding BP. Comprehensive testing involving 50 subjects reveal a standard deviation error of <inline-formula><tex-math notation="LaTeX">$ 4.27 \; \text{mmHg}$</tex-math></inline-formula> for diastolic pressure and <inline-formula><tex-math notation="LaTeX">$ 6.36 \; \text{mmHg}$</tex-math></inline-formula> for systolic pressure, respectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Mobile Computing
Published
2025-03-14
DOI
https://doi.org/10.1109/tmc.2025.3551315
Citations
4
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ubicon-BP: Towards Ubiquitous, Contactless Blood Pressure Detection Using Smartphone

Yanjiao Chen, Qingyong Hu, Yuan Wu, Min Li et al.
4 citations
IEEE Transactions on Mobile Computing
Non-Invasive Vital Sign Monitoring
2.70
article

Ubicon-BP: Towards Ubiquitous, Contactless Blood Pressure Detection Using Smartphone

Yanjiao Chen, Qingyong Hu, Yuan Wu, Min Li, Xinrong Hu, Bo Wang, Shoudu Bai
article en
4 citations

Abstract

Blood pressure (BP) is a critical physiological parameter closely associated with severe diseases such as heart failure and kidney damage. Current methods either require additional or dedicated hardware, or closing touching to the devices, causing discomfort and inconvenience. Therefore, a convenient, contactless BP measurement solution is highly desired. In this work, we present Ubicon-BP, a ubiquitous, device-free, and contactless BP detection application. Ubicon-BP calculates BP based on the pulse transit time (PTT), a key feature that is medically proven correlated with BP. However, using smartphone sensors to contactless calculate PTT is non-trivial since it requires a micro-second level precision for cardiac event detection. To address this issue, we propose leveraging the acoustic sensors in smartphone to detect vibrations caused by heart valve movements, as well as camera sensors to measure finger pulses. To accurately measure heartbeat signal that are susceptible to motion, we first improve the sensing granularity of acoustic signals and then introduce the IQ-MVED model to eliminate motion interference. Furthermore, when recovering pulse signals from video signals, issues such as poor generalization performance arise. Consequently, we propose the TS-CAN and meta-learning models to obtain personalized pulse signals. Finally, we transform the extracted time-frequency features from the recovered heartbeats and pulse signals to the corresponding BP. Comprehensive testing involving 50 subjects reveal a standard deviation error of <inline-formula><tex-math notation="LaTeX">$ 4.27 \; \text{mmHg}$</tex-math></inline-formula> for diastolic pressure and <inline-formula><tex-math notation="LaTeX">$ 6.36 \; \text{mmHg}$</tex-math></inline-formula> for systolic pressure, respectively.

IEEE Transactions on Mobile ComputingVol. 24(8)
Hong Kong University of Science and Technology (HK), Wuhan University (CN), Wuhan Textile University (CN), Zhejiang University (CN)
Gender equality
Openalex Percentile: Top 11%
Non-Invasive Vital Sign Monitoring
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.