Ubicon-BP: Towards Ubiquitous, Contactless Blood Pressure Detection Using Smartphone
Blood pressure (BP) is a critical physiological parameter closely associated with severe diseases such as heart failure and kidney damage. Current methods either require additional or dedicated hardware, or closing touching to the devices, causing discomfort and inconvenience. Therefore, a convenient, contactless BP measurement solution is highly desired. In this work, we present Ubicon-BP, a ubiquitous, device-free, and contactless BP detection application. Ubicon-BP calculates BP based on the pulse transit time (PTT), a key feature that is medically proven correlated with BP. However, using smartphone sensors to contactless calculate PTT is non-trivial since it requires a micro-second level precision for cardiac event detection. To address this issue, we propose leveraging the acoustic sensors in smartphone to detect vibrations caused by heart valve movements, as well as camera sensors to measure finger pulses. To accurately measure heartbeat signal that are susceptible to motion, we first improve the sensing granularity of acoustic signals and then introduce the IQ-MVED model to eliminate motion interference. Furthermore, when recovering pulse signals from video signals, issues such as poor generalization performance arise. Consequently, we propose the TS-CAN and meta-learning models to obtain personalized pulse signals. Finally, we transform the extracted time-frequency features from the recovered heartbeats and pulse signals to the corresponding BP. Comprehensive testing involving 50 subjects reveal a standard deviation error of <inline-formula><tex-math notation="LaTeX">$ 4.27 \; \text{mmHg}$</tex-math></inline-formula> for diastolic pressure and <inline-formula><tex-math notation="LaTeX">$ 6.36 \; \text{mmHg}$</tex-math></inline-formula> for systolic pressure, respectively.
Authors
- Yanjiao Chen (ORCID: https://orcid.org/0000-0002-1382-0679)
- Qingyong Hu (ORCID: https://orcid.org/0000-0003-0337-9207)
- Yuan Wu (ORCID: https://orcid.org/0000-0001-6173-2801)
- Min Li (ORCID: https://orcid.org/0000-0002-2959-9147)
- Xinrong Hu (ORCID: https://orcid.org/0000-0001-6563-669X)
- Bo Wang (ORCID: https://orcid.org/0009-0008-5284-2281)
- Shoudu Bai
Institutions
- Hong Kong University of Science and Technology (HK)
- Wuhan University (CN)
- Wuhan Textile University (CN)
- Zhejiang University (CN)
Publication Details
- Journal
- IEEE Transactions on Mobile Computing
- Published
- 2025-03-14
- DOI
- https://doi.org/10.1109/tmc.2025.3551315
- Citations
- 4
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 2.70