Investigation of Operating Temperature as a Key Factor in Determining Photovoltaic Module Cooling Specifications

Abstract Many studies have shown that the temperature of photovoltaic modules (PVM) significantly affects their performance. An effective thermal management system is required to maintain optimal efficiency. This investigation is part of an ongoing study on PVM thermal management that aims to maintain the PVM power output at high temperatures, that is, above 30°C. To design an efficient cooler, it is important to determine the operating temperature range of the PVM. This study focused on measuring the temperature of the back surface of a PVM with a capacity of 120 W using a thermocouple connected to a temperature data logger. Measurements were carried out in 3 (three) stages to improve the operating temperatures’ accuracy, accuracy, and trend. The first phase was carried out in September, October, November 2020, July 2021, and June 2023, from 6:00 am to 6:00 pm. The measurement was in the parking area on the second floor of the Faculty of Engineering, Pasundan University, Bandung. The results of the 3rd phase of the investigation revealed that the rear surface temperature ranged from 19°C in the morning at 06:00 to a peak of 64.5°C at 12:15 when the irradiance reached 535 W/m 2 . Then, the temperature gradually drops to approximately 30°C at 17:00 and drops back to approximately 24°C at sunset. Based on these findings, the optimal operating temperature range for PVM chillers is 30°C to 70°C, providing important data as a cooling design parameter.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-03-01
DOI
https://doi.org/10.1088/1742-6596/2972/1/012019
Citations
1
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Operating Temperature as a Key Factor in Determining Photovoltaic Module Cooling Specifications

Noreffendy Tamaldin, Toto Supriyono, Bambang Ariantara, Mohammad Yamin et al.
1 citations
Journal of Physics Conference Series
Photovoltaic System Optimization Techniques
0.36
article

Investigation of Operating Temperature as a Key Factor in Determining Photovoltaic Module Cooling Specifications

Noreffendy Tamaldin, Toto Supriyono, Bambang Ariantara, Mohammad Yamin, Ghazali Omar, Muhammad Rizki Sumartono, Dian Anisa Rokhwah Wati
article en
1 citations

Abstract

Abstract Many studies have shown that the temperature of photovoltaic modules (PVM) significantly affects their performance. An effective thermal management system is required to maintain optimal efficiency. This investigation is part of an ongoing study on PVM thermal management that aims to maintain the PVM power output at high temperatures, that is, above 30°C. To design an efficient cooler, it is important to determine the operating temperature range of the PVM. This study focused on measuring the temperature of the back surface of a PVM with a capacity of 120 W using a thermocouple connected to a temperature data logger. Measurements were carried out in 3 (three) stages to improve the operating temperatures’ accuracy, accuracy, and trend. The first phase was carried out in September, October, November 2020, July 2021, and June 2023, from 6:00 am to 6:00 pm. The measurement was in the parking area on the second floor of the Faculty of Engineering, Pasundan University, Bandung. The results of the 3rd phase of the investigation revealed that the rear surface temperature ranged from 19°C in the morning at 06:00 to a peak of 64.5°C at 12:15 when the irradiance reached 535 W/m 2 . Then, the temperature gradually drops to approximately 30°C at 17:00 and drops back to approximately 24°C at sunset. Based on these findings, the optimal operating temperature range for PVM chillers is 30°C to 70°C, providing important data as a cooling design parameter.

Journal of Physics Conference SeriesVol. 2972(1)
Technical University of Malaysia Malacca (MY), Gunadarma University (ID), Universitas Wahid Hasyim (ID), Universitas Pasundan (ID)
Openalex Percentile: Top 46%
Photovoltaic System Optimization Techniques
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.