Diffusion MRI with double diffusion encoding and variable mixing times disentangles water exchange from transient kurtosis

Double diffusion encoding (DDE) makes diffusion MRI sensitive to a wide range of microstructural features, and the acquired data can be analysed using different approaches. Correlation tensor imaging (CTI) uses DDE to resolve three components of the diffusional kurtosis: isotropic, anisotropic, and microscopic kurtosis. The microscopic kurtosis is estimated from the contrast between single diffusion encoding (SDE) and parallel DDE signals at the same b-value. Another approach is multi-Gaussian exchange (MGE), which employs DDE to measure exchange. Sensitivity to exchange is obtained by contrasting SDE and DDE signals at the same b-value. CTI and MGE exploit the same signal contrast to quantify microscopic kurtosis and exchange, and this study investigates the interplay between these two quantities. We perform Monte Carlo simulations in different geometries with varying levels of exchange and study the behaviour of the parameters from CTI and MGE. We conclude that microscopic kurtosis from CTI is sensitive to the exchange rate and that intercompartmental exchange and the transient kurtosis of individual compartments are distinct sources of microscopic kurtosis. In an attempt to disentangle these two sources, we propose a heuristic signal representation referred to as tMGE (MGE incorporating transient kurtosis) that accounts for both effects by exploiting the distinct signatures of exchange and transient kurtosis with varying mixing time: exchange causes a slow dependence of the signal on mixing time while transient kurtosis arguably has a much faster dependence. We find that applying tMGE to data acquired with multiple mixing times for both parallel and orthogonal DDE may enable estimation of the exchange rate as well as isotropic, anisotropic, and transient kurtosis.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-13
DOI
https://doi.org/10.1038/s41598-025-93084-4
Citations
4
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
5.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diffusion MRI with double diffusion encoding and variable mixing times disentangles water exchange from transient kurtosis

Arthur Chakwizira, Markus Nilsson, Filip Szczepankiewicz
4 citations
Scientific Reports
Advanced Neuroimaging Techniques and Applications
5.44
article

Diffusion MRI with double diffusion encoding and variable mixing times disentangles water exchange from transient kurtosis

Arthur Chakwizira, Markus Nilsson, Filip Szczepankiewicz
article en
4 citations

Abstract

Double diffusion encoding (DDE) makes diffusion MRI sensitive to a wide range of microstructural features, and the acquired data can be analysed using different approaches. Correlation tensor imaging (CTI) uses DDE to resolve three components of the diffusional kurtosis: isotropic, anisotropic, and microscopic kurtosis. The microscopic kurtosis is estimated from the contrast between single diffusion encoding (SDE) and parallel DDE signals at the same b-value. Another approach is multi-Gaussian exchange (MGE), which employs DDE to measure exchange. Sensitivity to exchange is obtained by contrasting SDE and DDE signals at the same b-value. CTI and MGE exploit the same signal contrast to quantify microscopic kurtosis and exchange, and this study investigates the interplay between these two quantities. We perform Monte Carlo simulations in different geometries with varying levels of exchange and study the behaviour of the parameters from CTI and MGE. We conclude that microscopic kurtosis from CTI is sensitive to the exchange rate and that intercompartmental exchange and the transient kurtosis of individual compartments are distinct sources of microscopic kurtosis. In an attempt to disentangle these two sources, we propose a heuristic signal representation referred to as tMGE (MGE incorporating transient kurtosis) that accounts for both effects by exploiting the distinct signatures of exchange and transient kurtosis with varying mixing time: exchange causes a slow dependence of the signal on mixing time while transient kurtosis arguably has a much faster dependence. We find that applying tMGE to data acquired with multiple mixing times for both parallel and orthogonal DDE may enable estimation of the exchange rate as well as isotropic, anisotropic, and transient kurtosis.

Scientific ReportsVol. 15(1)
Lund University (SE), Skåne University Hospital (SE)
Lunds Universitet
Clean water and sanitation
Openalex Percentile: Top 5%
Advanced Neuroimaging Techniques and Applications
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.