Impact of Cooler Temperature Variations on Flow Boiling Phenomena in a Natural Circulation Rectangular Loop

Abstract The passive cooling system that utilizes natural circulation is effective in removing decay heat from nuclear reactors, with the direct passive residual heat removal system being the most efficient. This study employs the Rectangular-TP FASSIP-04 Ver.2 Loop with a direct heating model to investigate two-phase natural circulation flow. The coolant water temperature is set at 10°C, 15°C, and 20°C with a constant heating power of 5600 watts, to measure temperature characteristics, flow rate, flow regimes, and heat removal rate. The results show that higher coolant temperatures accelerate the achievement of steady-state conditions, reduce the average steady-state temperature, and increase the flow rate and Reynolds number. In contrast, lower coolant temperatures accelerate temperature drop and improve heat removal effectiveness during the transient cooling phase, as well as help maintain flow stability. These findings highlight the importance of controlling coolant temperature in influencing the thermal dynamics and flow stability of the system.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-03-01
DOI
https://doi.org/10.1088/1742-6596/2972/1/012020
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Cooler Temperature Variations on Flow Boiling Phenomena in a Natural Circulation Rectangular Loop

Mulya Juarsa, Wayan Nata Septiadi, Dwi Yuliaji, Nur Rochman Budiyanto et al.
Journal of Physics Conference Series
Nuclear Engineering Thermal-Hydraulics
article

Impact of Cooler Temperature Variations on Flow Boiling Phenomena in a Natural Circulation Rectangular Loop

Mulya Juarsa, Wayan Nata Septiadi, Dwi Yuliaji, Nur Rochman Budiyanto, Arif Adtyas Budiman, Adhika Enggar Pamungkas, Ryan Oktaviandi, Sunandi Kharisma, Muhammad Rafel, Shendy Akbar Maryadi, Putut Hery Setiyawan
article en

Abstract

Abstract The passive cooling system that utilizes natural circulation is effective in removing decay heat from nuclear reactors, with the direct passive residual heat removal system being the most efficient. This study employs the Rectangular-TP FASSIP-04 Ver.2 Loop with a direct heating model to investigate two-phase natural circulation flow. The coolant water temperature is set at 10°C, 15°C, and 20°C with a constant heating power of 5600 watts, to measure temperature characteristics, flow rate, flow regimes, and heat removal rate. The results show that higher coolant temperatures accelerate the achievement of steady-state conditions, reduce the average steady-state temperature, and increase the flow rate and Reynolds number. In contrast, lower coolant temperatures accelerate temperature drop and improve heat removal effectiveness during the transient cooling phase, as well as help maintain flow stability. These findings highlight the importance of controlling coolant temperature in influencing the thermal dynamics and flow stability of the system.

Journal of Physics Conference SeriesVol. 2972(1)
Udayana University (ID), Universitas Gadjah Mada (ID), Universitas Ibn Khaldun Bogor (ID), National Nuclear Energy Agency of Indonesia (ID)
Badan Riset dan Inovasi Nasional, Lembaga Pengelola Dana Pendidikan
Openalex Percentile: Top 94%
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.