Optimum design of double tuned mass dampers using multiple metaheuristic multi-objective optimization algorithms under seismic excitation

The tuned mass damper is one of the most frequently employed structural control devices for mitigating dynamic vibrations in structures subjected to earthquake ground motions. Conventional tuned mass dampers require substantial mass to effectively reduce the structure’s vibration. However, implementing multiple-tuned mass dampers can also improve seismic performance while reducing the required mass. The dynamic characteristics of these devices play a critical role in enhancing the effectiveness of multiple-tuned mass dampers and the seismic performance of the structure. This study investigates the efficiency of double-tuned mass dampers and the optimization of their dynamic characteristics to minimize structural displacement and acceleration. The tuning process is carried out using a combination of Pareto front derived from seven multi-objective metaheuristic optimization algorithms with two objectives. The proposed methodology is applied to a 10-floor case study, using ground acceleration time histories to evaluate its seismic performance. To demonstrate the efficiency of the proposed method, the results are compared with those from a double-tuned mass damper system and an uncontrolled structure. The evaluation is carried out using seven earthquake ground motion records in addition to one benchmark record. The findings show that employing optimally tuned double-tuned mass dampers reduced acceleration by 30% and displacement by 50%. The numerical results confirmed that the proposed methodology effectively identifies the optimal double-tuned mass damper configuration under earthquake excitation.

Authors

Institutions

Publication Details

Journal
Frontiers in Built Environment
Published
2025-03-13
DOI
https://doi.org/10.3389/fbuil.2025.1559530
Citations
8
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
7.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimum design of double tuned mass dampers using multiple metaheuristic multi-objective optimization algorithms under seismic excitation

Ataallah Sadeghi-Movahhed, Ehsan Noroozinejad Farsangi, Fadli Emsa Zamani, Ali Majdi et al.
8 citations
Frontiers in Built Environment
Structural Health Monitoring Techniques
7.63
article

Optimum design of double tuned mass dampers using multiple metaheuristic multi-objective optimization algorithms under seismic excitation

Ataallah Sadeghi-Movahhed, Ehsan Noroozinejad Farsangi, Fadli Emsa Zamani, Ali Majdi, ‪Mohammadreza Mashayekhi, Sayyed Hadi Alavi
article en
8 citations

Abstract

The tuned mass damper is one of the most frequently employed structural control devices for mitigating dynamic vibrations in structures subjected to earthquake ground motions. Conventional tuned mass dampers require substantial mass to effectively reduce the structure’s vibration. However, implementing multiple-tuned mass dampers can also improve seismic performance while reducing the required mass. The dynamic characteristics of these devices play a critical role in enhancing the effectiveness of multiple-tuned mass dampers and the seismic performance of the structure. This study investigates the efficiency of double-tuned mass dampers and the optimization of their dynamic characteristics to minimize structural displacement and acceleration. The tuning process is carried out using a combination of Pareto front derived from seven multi-objective metaheuristic optimization algorithms with two objectives. The proposed methodology is applied to a 10-floor case study, using ground acceleration time histories to evaluate its seismic performance. To demonstrate the efficiency of the proposed method, the results are compared with those from a double-tuned mass damper system and an uncontrolled structure. The evaluation is carried out using seven earthquake ground motion records in addition to one benchmark record. The findings show that employing optimally tuned double-tuned mass dampers reduced acceleration by 30% and displacement by 50%. The numerical results confirmed that the proposed methodology effectively identifies the optimal double-tuned mass damper configuration under earthquake excitation.

Frontiers in Built EnvironmentVol. 11
Alsalam University College (IQ), Islamic Azad University Shabestar (IR), Western Sydney University (AU), K. N. Toosi University of Technology (IR)
Openalex Percentile: Top 3%
Structural Health Monitoring Techniques
7.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.