Impact of Concrete Grade and Stirrups Spacing on Performance Enhancement of Hybrid T-Beams Using Lightweight Concrete and High Compressive Strength Combinations

This study examines the performance of a total of ten reinforced concrete T-beams, nine of which were made as hybrid beams by casting the web with LW concrete and the flange with HS concrete; the last beam was cast as a normal beam (entirely cast with HS concrete). All beams underwent testing under two-point loads following a 28-day period. The variables of the experimental program include the concrete grade within the web (46, 62, and 82 MPa) and stirrup distribution distances (100, 200, and 300 mm). The experimental program includes load-deflection curves and failure modes for hybrid and normal beams. The results showed that all the beams failed in shear-flexural mode. Also, increasing flange compressive strength increased shear. strength. Increasing stirrup distribution distance from 100 to 200 and 300 mm reduced the ultimate load capacity; specimens with stirrup spacing of 300 mm failed directly after yielding of steel due to crushing the concrete over the support and spalling concrete cover within the shear zone. The study also determined that reducing stirrup spacing to 100 mm did not alter the failure mode, as shear failure was dictated by the compressive strength of the lower layer of the hybrid beams (19 MPa compressive strength of LW concrete).

Authors

Institutions

Publication Details

Journal
International Journal of Mechanical, Electrical and Civil Engineering.
Published
2025-03-13
DOI
https://doi.org/10.61132/ijmecie.v2i2.245
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Concrete Grade and Stirrups Spacing on Performance Enhancement of Hybrid T-Beams Using Lightweight Concrete and High Compressive Strength Combinations

Hammad D. Merie, Ibrahim Idrees Ezzulddin
International Journal of Mechanical, Electrical and Civil Engineering.
Structural Load-Bearing Analysis
article

Impact of Concrete Grade and Stirrups Spacing on Performance Enhancement of Hybrid T-Beams Using Lightweight Concrete and High Compressive Strength Combinations

Hammad D. Merie, Ibrahim Idrees Ezzulddin
article en

Abstract

This study examines the performance of a total of ten reinforced concrete T-beams, nine of which were made as hybrid beams by casting the web with LW concrete and the flange with HS concrete; the last beam was cast as a normal beam (entirely cast with HS concrete). All beams underwent testing under two-point loads following a 28-day period. The variables of the experimental program include the concrete grade within the web (46, 62, and 82 MPa) and stirrup distribution distances (100, 200, and 300 mm). The experimental program includes load-deflection curves and failure modes for hybrid and normal beams. The results showed that all the beams failed in shear-flexural mode. Also, increasing flange compressive strength increased shear. strength. Increasing stirrup distribution distance from 100 to 200 and 300 mm reduced the ultimate load capacity; specimens with stirrup spacing of 300 mm failed directly after yielding of steel due to crushing the concrete over the support and spalling concrete cover within the shear zone. The study also determined that reducing stirrup spacing to 100 mm did not alter the failure mode, as shear failure was dictated by the compressive strength of the lower layer of the hybrid beams (19 MPa compressive strength of LW concrete).

International Journal of Mechanical, Electrical and Civil Engineering.Vol. 2(2)
University of Kirkuk (IQ)
Openalex Percentile: Top 95%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Concrete Grade and Stirrups Spacing on Performance Enhancement of Hybrid T-Beams Using Lightweight Concrete and High Compressive Strength Combinations — Hammad D. Merie, Ibrahim Idrees Ezzulddin · International Journal of Mechanical, Electrical and Civil Engineering. (2025) | TGRS Research Map | TGRS