Analysis of ground leakage issues due to incorrect wiring in low voltage distribution substation area

The low-voltage distribution substation area supplies many users through complex feeders, with leakage faults common in residential and industrial settings, posing serious safety risks. Neutral-to-ground wiring errors causing leakage faults are widespread and challenging to detect due to hidden fault locations and lack of visible insulation breakdown. These issues hinder RCD deployment and are a major cause of electric shocks and fires. This paper reviews the existing three-tier leakage protection and grounding framework, investigates the mechanisms of neutral-ground miswiring, and establishes a residual current model for substations. It also analyzes dangerous voltages in TT and TN-C-S grounding systems from these faults, assessing safety risks for users and proposing targeted countermeasures.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-03-01
DOI
https://doi.org/10.1049/icp.2025.0669
Primary Topic
Embedded Systems and FPGA Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of ground leakage issues due to incorrect wiring in low voltage distribution substation area

Yibo Zhou, Yunfei Huang, Zhixun Luo, Sheng Su et al.
IET conference proceedings.
Embedded Systems and FPGA Design
article

Analysis of ground leakage issues due to incorrect wiring in low voltage distribution substation area

Yibo Zhou, Yunfei Huang, Zhixun Luo, Sheng Su, Lina He
article en

Abstract

The low-voltage distribution substation area supplies many users through complex feeders, with leakage faults common in residential and industrial settings, posing serious safety risks. Neutral-to-ground wiring errors causing leakage faults are widespread and challenging to detect due to hidden fault locations and lack of visible insulation breakdown. These issues hinder RCD deployment and are a major cause of electric shocks and fires. This paper reviews the existing three-tier leakage protection and grounding framework, investigates the mechanisms of neutral-ground miswiring, and establishes a residual current model for substations. It also analyzes dangerous voltages in TT and TN-C-S grounding systems from these faults, assessing safety risks for users and proposing targeted countermeasures.

IET conference proceedings.Vol. 2024(33)
Changsha University of Science and Technology (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 95%
Embedded Systems and FPGA Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of ground leakage issues due to incorrect wiring in low voltage distribution substation area — Yibo Zhou, Yunfei Huang, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS