Study on storm disaster of 10 kV distribution network facilities in Nanning based on FloodArea

The problem of heavy rainfall disasters due to heavy rainfall extremes, such as typhoons and torrential rains, has become frequent, and many cities still lack precautions against sudden extreme weather disasters brought about by climate change. The precautionary standards of some urban infrastructures have failed to keep up with historical climatic changes, such as facilities such as distribution substations and distribution rooms, which are more prone to failures in flooding disasters. Based on the principle of hydrodynamics and the basic assumption of active inundation caused by rainfall, inundation simulation calculations of flooding caused by rainfall in Nanning are carried out by using high-resolution geographic information data and GIS raster analysis technology based on the FloodArea model. Then the inundation range and water depth of different rainfall scenarios are simulated to determine the different disaster-causing levels of distribution network equipment in the study area.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-03-01
DOI
https://doi.org/10.1049/icp.2025.0674
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on storm disaster of 10 kV distribution network facilities in Nanning based on FloodArea

Pengxin Deng, Jing Zhu, Jinhong Rong
IET conference proceedings.
Smart Grid and Power Systems
article

Study on storm disaster of 10 kV distribution network facilities in Nanning based on FloodArea

Pengxin Deng, Jing Zhu, Jinhong Rong
article en

Abstract

The problem of heavy rainfall disasters due to heavy rainfall extremes, such as typhoons and torrential rains, has become frequent, and many cities still lack precautions against sudden extreme weather disasters brought about by climate change. The precautionary standards of some urban infrastructures have failed to keep up with historical climatic changes, such as facilities such as distribution substations and distribution rooms, which are more prone to failures in flooding disasters. Based on the principle of hydrodynamics and the basic assumption of active inundation caused by rainfall, inundation simulation calculations of flooding caused by rainfall in Nanning are carried out by using high-resolution geographic information data and GIS raster analysis technology based on the FloodArea model. Then the inundation range and water depth of different rainfall scenarios are simulated to determine the different disaster-causing levels of distribution network equipment in the study area.

IET conference proceedings.Vol. 2024(33)
Changsha University of Science and Technology (CN)
Climate action
Openalex Percentile: Top 96%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on storm disaster of 10 kV distribution network facilities in Nanning based on FloodArea — Pengxin Deng, Jing Zhu, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS