Use of the Electrified Wire Technique for In Situ Fenestration Creation Within a Branch Bridging Stent
The electrified wire technique may be used as bailout for in situ fenestration creation in unintended coverage of early TV side-branches.Clinical ImpactAnatomic variations may increase the technical complexity of branched endovascular aortic repair while technical pitfalls related to target vessel preservation may demand the application of bailout techniques. In this case, the electrified wire technique was used to create an in situ fenestration within the bridging stent of a celiac artery (CA) and superior mesenteric artery common trunk (anatomic variation), after bridging stent unmount during advancement and CA unintended coverage.
Authors
- José I. Torrealba (ORCID: https://orcid.org/0000-0001-7595-9337)
- Tilo Kölbel (ORCID: https://orcid.org/0000-0002-9962-0204)
- Giuseppe Panuccio (ORCID: https://orcid.org/0000-0002-8477-661X)
- Petroula Nana (ORCID: https://orcid.org/0000-0001-9060-8519)
- Fiona Rohlffs (ORCID: https://orcid.org/0000-0002-0460-1589)
- Kugarajah Arulrajah (ORCID: https://orcid.org/0009-0000-8090-0655)
- Antonino Giordano (ORCID: https://orcid.org/0000-0003-3657-7584)
Institutions
- Universität Hamburg (DE)
- University Medical Center Hamburg-Eppendorf (DE)
Publication Details
- Journal
- Journal of Endovascular Therapy
- Published
- 2025-03-13
- DOI
- https://doi.org/10.1177/15266028251324074
- Citations
- 2
- Primary Topic
- Aortic Disease and Treatment Approaches
- Type
- article
- Field-Weighted Citation Impact
- 3.04