Quantifying multi‐institutional ADC measurement variability of 1.5 T MR‐Linacs: A phantom and in vivo study

This study demonstrated accuracy, intra-scanner repeatability, and inter-scanner reproducibility comparable to metrics reported in the literature, using both the phantom and volunteer datasets. The cervix sequence had the largest variability in both phantom and volunteer results and was recommended for further investigation. This study suggests that qMRI techniques utilizing DWI could be a viable option for future multi-centered patient-based studies utilizing Australian MRLs, with phantom-based quality assurance recommended alongside patient imaging.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-03-13
DOI
https://doi.org/10.1002/mp.17739
Citations
4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
5.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying multi‐institutional ADC measurement variability of 1.5 T MR‐Linacs: A phantom and in vivo study

Satomi Higuchi, Michael Jameson, Hilary L. Byrne, Amy Walker et al.
4 citations
Medical Physics
Advanced MRI Techniques and Applications
5.44
article

Quantifying multi‐institutional ADC measurement variability of 1.5 T MR‐Linacs: A phantom and in vivo study

Satomi Higuchi, Michael Jameson, Hilary L. Byrne, Amy Walker, Sarah Alexandra Elliott, Vikneswary Batumalai, John Baines, Madeline Carr, Lois Holloway, Peter Metcalfe, Kathryn E. Keenan, Michaela Beavan
article en
4 citations

Abstract

This study demonstrated accuracy, intra-scanner repeatability, and inter-scanner reproducibility comparable to metrics reported in the literature, using both the phantom and volunteer datasets. The cervix sequence had the largest variability in both phantom and volunteer results and was recommended for further investigation. This study suggests that qMRI techniques utilizing DWI could be a viable option for future multi-centered patient-based studies utilizing Australian MRLs, with phantom-based quality assurance recommended alongside patient imaging.

Medical PhysicsVol. 52(6)
National Institute of Standards and Technology (US), University of Wollongong (AU), Peter MacCallum Cancer Centre (AU), Townsville Hospital (AU), UNSW Sydney (AU), Australian and New Zealand Intensive Care Society (AU), The George Institute for Global Health (AU), Ingham Institute (AU), Olivia Newton-John Cancer Wellness & Research Centre (AU), Austin Health (AU), University of Newcastle Australia (AU), James Cook University (AU)
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.