Reproducibility of tailored and universal nonselective excitation pulses at <scp>7 T</scp> for human cardiac <scp>MRI</scp> : A 3‐year and an interday study

Although TPs showed advantages when tailored for a specific target volume, they struggled with long-term consistency and required lengthy calibration. The precomputed UP kT-points pulses proved to be the most consistent across all scans acquired in the 3 years by different operators, minimizing CV-data dispersion and maintaining FA uniformity.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2025-03-13
DOI
https://doi.org/10.1002/mrm.30495
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study

Sebastian Schmitter, Jean Pierre Bassenge, Jeanette Schulz‐Menger, Sebastian Dietrich et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study

Sebastian Schmitter, Jean Pierre Bassenge, Jeanette Schulz‐Menger, Sebastian Dietrich, Christoph Stefan Aigner, M. Alarcón
article en

Abstract

Although TPs showed advantages when tailored for a specific target volume, they struggled with long-term consistency and required lengthy calibration. The precomputed UP kT-points pulses proved to be the most consistent across all scans acquired in the 3 years by different operators, minimizing CV-data dispersion and maintaining FA uniformity.

Magnetic Resonance in MedicineVol. 94(2)
Physikalisch-Technische Bundesanstalt (DE), University of Minnesota (US), German Cancer Research Center (DE), Max Delbrück Center (DE), Heidelberg University (DE), Max Planck Institute for Human Development (DE), German Centre for Cardiovascular Research (DE), Helios Hospital Berlin-Buch (DE), Resonance Research (United States) (US), Charité - Universitätsmedizin Berlin (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 93%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reproducibility of tailored and universal nonselective excitation pulses at <scp>7 T</scp> for human cardiac <scp>MRI</scp> : A 3‐year and an interday study — Sebastian Schmitter, Jean Pierre Bassenge, et al. · Magnetic Resonance in Medicine (2025) | TGRS Research Map | TGRS