Electrical impedance tomography in critical care: Advancing bedside respiratory monitoring and ventilation management

Electrical Impedance Tomography (EIT) is a transformative, non-invasive imaging tool in critical care, providing real-time, continuous monitoring of lung function. Originally applied to assess ventilation distribution in mechanically ventilated patients. EIT's scope has expanded significantly. It now encompasses a wide range of applications, including positive end-expiratory pressure (PEEP) titration, spontaneous breathing assessment, air trapping detection, alveolar recruitment guidance, and ventilation-perfusion (V/Q) matching. EIT supports personalized respiratory management across a range of therapies, including mechanical ventilation, high-flow nasal cannula (HFNC), and non-invasive ventilation (NIV), by identifying ventilation heterogeneity and preventing ventilator-induced lung injury (VILI). The ability of EIT to quantify regional lung mechanics, detect changes due to therapeutic interventions like suctioning and bronchodilation, and visualize complex phenomena such as pendelluft underscores its role in optimizing ventilation strategies and enhancing patient outcomes in critical care. Despite some technical challenges, EIT's integration into respiratory monitoring protocols is advancing, supporting data-driven, individualized management approaches that improve safety and outcomes for critically ill patients.

Authors

Institutions

Publication Details

Journal
Clinical Critical Care
Published
2025-03-13
DOI
https://doi.org/10.54205/ccc.v33.272709
Citations
1
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical impedance tomography in critical care: Advancing bedside respiratory monitoring and ventilation management

Ranistha Ratanarat, Jitanong Sootlek
1 citations
Clinical Critical Care
Respiratory Support and Mechanisms
1.52
article

Electrical impedance tomography in critical care: Advancing bedside respiratory monitoring and ventilation management

Ranistha Ratanarat, Jitanong Sootlek
article en
1 citations

Abstract

Electrical Impedance Tomography (EIT) is a transformative, non-invasive imaging tool in critical care, providing real-time, continuous monitoring of lung function. Originally applied to assess ventilation distribution in mechanically ventilated patients. EIT's scope has expanded significantly. It now encompasses a wide range of applications, including positive end-expiratory pressure (PEEP) titration, spontaneous breathing assessment, air trapping detection, alveolar recruitment guidance, and ventilation-perfusion (V/Q) matching. EIT supports personalized respiratory management across a range of therapies, including mechanical ventilation, high-flow nasal cannula (HFNC), and non-invasive ventilation (NIV), by identifying ventilation heterogeneity and preventing ventilator-induced lung injury (VILI). The ability of EIT to quantify regional lung mechanics, detect changes due to therapeutic interventions like suctioning and bronchodilation, and visualize complex phenomena such as pendelluft underscores its role in optimizing ventilation strategies and enhancing patient outcomes in critical care. Despite some technical challenges, EIT's integration into respiratory monitoring protocols is advancing, supporting data-driven, individualized management approaches that improve safety and outcomes for critically ill patients.

Clinical Critical Care
Siriraj Hospital (TH), Mahidol University (TH)
Openalex Percentile: Top 21%
Respiratory Support and Mechanisms
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrical impedance tomography in critical care: Advancing bedside respiratory monitoring and ventilation management — Ranistha Ratanarat, Jitanong Sootlek · Clinical Critical Care (2025) | TGRS Research Map | TGRS